CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
29
Long Test with Loopback
This test is entered by pressing the advance switch only while powering up the unit with
the on/off switch. Special loopback connectors should be connected to each Caretaker
Plus port.
Tests 1-5
- These are the same as tests 1-5 of long test without loopback.
Test 6
- The loopback test assures that all port signals are functional. In order for this
test to pass, special loopback connectors must be installed on each port, see TABLE 9.
if this test fails (ERROR LED and LED #6 are lit) then a port communication chip has
failed and the unit must be serviced.
The advance switch may be pressed to determine which port is the failing port. MODE,
DATA, and BUSY will all be flashing. The LEDs of all ports which pass will be flashing. A
failing port will have its corresponding LED steadily lit (ERROR LED is used for port O).
Ports not installed will have their corresponding LEDs off. The select switch may be
pressed to execute the test again. In order to bypass this test completely, both the
advance and the select switched may be pressed.
Table 9. Loopback Test Connectors
Serial Loopback
Connector
Male 25 Pin D
Parallel Loopback
Connector
Male 36 Pin Centronics
Parallel Loopback
Connector
Male 25 Pin D
2……..….3
6……….20
1……..….8
2……….13
3……….32
4……….12
5……….31
6……….36
7…..10, 14
9……….11
1…..…….8
3……….15
4……….12
5……….16
6……….17
7…..10, 14
9……….11
Summary of Contents for Caretaker Plus CTP-4P
Page 2: ......
Page 39: ......
Page 40: ...10707 Stancliff Road Phone 281 933 7673 Houston Texas 77099 WWW ROSE COM ...