Rosco Vapour Operating Instructions Manual Download Page 9

- 8 -

OPERATING THE MACHINE

Powering On

Make sure the unit is plugged in.  Turn on the Main Power Switch that is located next to the power cord 
on the rear of the machine.  The red Power Indicator light on the Remote Control Panel will illuminate.  
If the Power Indicator light does NOT illuminate, press and release the Standby Button on the Remote 
Control Panel. 

Heating

When switched on, the red Heat Indicator light will illuminate and the machine will begin to heat up to 
its optimal temperature.  The initial heating cycle will take 7-10 minutes.  When the green Ready Indica-
tor light comes on, the machine is ready to make fog.  Note:  If no remote is connected and no DMX signal 
is detected, the machine will not heat.

Control Options

There are several methods of controlling the Vapour , including: Manual Control via the Remote Control 
Panel, DMX control via a lighting console and Multi-Link control that allows multiple machines to be 
controlled from a single Remote Control Panel.
Manual Control via the Detachable Remote Control Panel that is included with each machine.  An oper-
ator can control the unit at the machine, or from a distance using the included 3-pin cable.  The Remote 
Control Panel can be used to set fog output volume, power the machine on and off using Standby mode, 
and set a repeating, timed cycle of on/off operation.
DMX Control from your lighting desk is available as a standard option. The Vapour will use one channel 
of DMX control for output volume.
Multi-Link allows up to 4 machines to be linked together via 3pin XLR cables (not included) and con-
trolled by a single Remote Control Panel. 

Using the Remote Control Panel

The Remote Control Panel can be operated directly on the machine or detached from the unit and used 
at a distance.  To detach the Remote Control Panel from the unit, loosen the thumb screws and lift the 
panel from its recessed mount.  A 15 foot (4.5m) cable is provided to allow the machine to be operated at 
a distance.  If needed, a longer 3-pin XLR cable can be used or joined to the existing cable.  Do not exceed 
a maximum distance of 165 feet (50 m) from remote to machine.
When the green Ready Indicator light is illuminated, the Vapour is ready to make fog.   Press and release 
the Fog Button to begin producing fog.  The red Power Indicator light will flash to indicate the machine 
is operating. To stop making fog, press and release the Fog Button again. Adjust the Fog Level knob to 
increase or decrease the amount of fog produced.
The Standby Button allows the machine to be “turned off” from the remote without using the Main 
Power Switch.  In Standby mode, the machine will not reheat or make fog, the pump remains unpowered 
and all indicator lights will switch off.  To engage Standby mode, press and release the Standby Button.  
The red Power Indicator light will turn off.  To disengage Standby mode, press and release the Standby 
Button again and the red Power Indicator light will turn back on.  Once Standby mode is disengaged, the 
machine will immediately start heating in preparation to make fog.  Note:  If no remote is connected and 
no DMX signal is detected, the machine will not heat.
Using Timers
The timer controls allow you to set the machine to produce fog in timed intervals without an operator. 
To engage the timers, press and release the Timer Button. The green Timer Indicator light will illuminate 
and the machine will begin to produce fog at the level set by the Fog Level Knob, and the red Power 
Indicator light will flash to indicate the machine is operating. 

Summary of Contents for Vapour

Page 1: ...www rosco com Vapour Fog Machine Operating Instructions READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...l 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 9 Using DMX Control 9 10 Connecting the DMX 9 Setting the DMX Address 9 DMX Operation 10 Using Multi Link 10 Changing Fluid 11 Running Dry 11 Priming the System 11 Powering Down 11 Troubleshooting 12 Ducting Fog 12 Maintenance 13 Exterior Cleaning 13 Maintaining the Heat Exchanger 13 Using the Air Input Connection 13 Storage and Shipme...

Page 3: ...n genuine Rosco fog fluids as they have not been tested for opti mal performance and safety considerations Doing so may damage the machine and will void the warranty The Rosco Vapour has been tested for use in professional theatrical productions and is included under the Equipment Based Guidelines of the Equity League Pension and Health Trust Funds The Vapour is also compliant with the Alliance of...

Page 4: ...ny machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unusual behavior disconnect machine immediately from power and send machine to a Service Center for repair Disconnect unit from power source before servicing and when not in use Preventing Burns and Fi...

Page 5: ...the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine including the indicator lights Do Not Touch the shielded nozzle of the machine Allow sufficient cooling time after operation before attempting to perform maintenance or storage Do Not Direct the fog output...

Page 6: ...off by controlling the flow of power to the unit Air Input Purge Connection This is a push to connect inlet that accepts OD tubing and allows com pressed air to blow through the heat exchanger for cleaning and maintenance Heat Indicator A red indicator light that illuminates when machine is heating in order to achieve optimal temperature for producing fog Fluid Bottle Ready Indicator A green indic...

Page 7: ...isabled if Standby mode is engaged Fog Level Knob Rotate to set the desired amount of fog output Higher numbers indicate more fog Output is controlled by pump speed increasing and sending more fog fluid into the heat exchanger Fog On Knob Used only when timer control is engaged Rotate to set the desired time interval that the machine will produce fog During fog production the Power Indicator light...

Page 8: ...p along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Rosco fog and haze machines are primed at the factory with a small amount of fluid No additional priming should be necessary for proper fog output If fog output is diminished or intermittent see the Priming the System section of this manual for instructions on how to re prime the fluid path Power Connec...

Page 9: ... Control Panel can be operated directly on the machine or detached from the unit and used at a distance To detach the Remote Control Panel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cable can be used or joined to the existing cable Do not exceed a ma...

Page 10: ... to have the Remote Control Panel attached when controlling the machine via DMX However if no Remote Control Panel is attached and no DMX signal is present the machine will not heat up It is not necessary to send a command via DMX to start the heating process Once a valid DMX signal from an appropriate DMX control device is detected the Vapour will begin its heating process Setting the DMX Address...

Page 11: ...Panel and its 3 pin XLR cable from the second machine Connect the plug of the cable from the Head Machine into the remote port of the second machine where the Remote Control Panel had previously been connected Repeat this process to connect a third and or fourth machine No additional set up is required The Remote Control Panel attached to the head machine will operate all machines in the Multi Lin...

Page 12: ...rs after power is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instruc tions listed under Maintenance to prepare the machine for long term storage DUCTING FOG It is often desirable to duct fog from the machine to another location on stage or in a set This can be accomplished using flexible hose dryer hose or similar large diameter ducting su...

Page 13: ... priming See the Priming the System section of the manual Heat exchanger is clogged Contact nearest Service Center for repair Machine produces fog intermittently when fog button is not pressed Timer is engaged Turn timers off by pressing Timer Button Green Timer Indicator light should not be illuminated Machine works via the Remote Control Panel but not from DMX DMX address setting incorrect Check...

Page 14: ...dically to ensure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air For lasting performance Rosco recommends purging the heat exchanger once a week while in production and before storing the machine for extended periods of time Rosco does not recommend th...

Page 15: ... 10 minutes Control and programming Control options DMX timer remote DMX channels 1 Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections DMX 5 pin XLR Remote Multi Link 3 pin XLR AC power Fixed power cable Electrical AC voltage 120V 230V 50 60Hz Main fuse 120V US version 10AT Main fuse 230V EU version 5AT Thermal Maximum ambient temperature 40 C 104 F Ext...

Page 16: ... 15 Dimensions Dimensions are shown in inches and millimeters ...

Page 17: ...r damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect improper shipping damage caused by disasters such as flood fire and lightning improper elec trical current or conn...

Page 18: ...1 2007 Generic Immunity Standard for residential and light Industrial environments 60335 1 2002 A15 2011 Safety of household and similar electrical appliances BS EN 62233 2008 Electromagnetic fields These standards reference the following European standards Emissions EN 55 022 B RF voltage and field strength EN61000 3 3 Flicker EN 55 014 RF voltage discontinuous Immunity EN 61000 4 2 Electrostatic...

Reviews: