5.1
Construction see dimensions on the following page
Minimum area for reinforcement of wall. Wall material must be suitable for screw
mounting.
Area for electric installation.
Area for conduit.
Cabinet height of 70.4cm or more. For cabinet heights above 70.4cm a fixed shelf is placed in
the upper part of the cabinet (see illustration).
Cable for operation must be laid from the cabinet to the front edge of the worktop for mounting
of the control switch. We recommend the installation of an empty conduit in the wall to
accommodate the cable (ø3.5cm).
If a high cabinet stands in the immediate vicinity of Verti-Inside, the cable may be run through
the cabinet to avoid the conduit in the wall.
Max. load 80kg evenly distributed over all three shelves for cabinets up to 100cm in width,
according to DS/EN 12182, based on 8 screws/bolts.
Minimum load capacity per screw/bolt:
10.5kg
The fitter should always consider the material, condition and strength of the wall and use screws
and rawlplugs suitable for the specific wall type.