background image

Page 1  

© ROPOX 2017 

 
 

 

Ropox Verti-Inside 

User Manual 
Mounting Instructions 
Service Manual 

Keep this folder with the product at all times! 

 
 

 

 

 

 

 

 

 

 

PDF 6116 / 01.07.2019 

 

QR code to 
mounting 
video 

Summary of Contents for Verti-Inside

Page 1: ...Page 1 ROPOX 2017 Ropox Verti Inside User Manual Mounting Instructions Service Manual Keep this folder with the product at all times PDF 6116 01 07 2019 QR code to mounting video ...

Page 2: ... diagram 8 6 MOUNTING INSTRUCTIONS 8 7 PERFORMANCE TEST 18 8 LIST OF COMPONENTS VERTI INSIDEELECTRIC 19 9 OPTIONS VERTI INSIDEELECTRIC 20 10 PLACING OF LED SPOT 22 11 CABLES FOR LED SPOT 22 12 SAFETY IN USE 24 13 CLEANING MAINTENANCE 25 13 1 Cleaning of frame 25 13 2 Maintenance 25 13 3 Service schedule operation and maintenance 26 14 FAULT FINDING 26 14 1 The frame cannot be adjusted in height ad...

Page 3: ... otherwise combined with other electrical components the assembly will be considered a new unit which must be subjected to a risk assessment to obtain CE marking 3 Application Verti Inside is designed to obtain optimum working height for the user Verti Inside is designed to adjust the height of wall cupboards Verti Inside must NOT be used as a lifting unit or person lifter The product must be used...

Page 4: ...pth 31cm 30 40416 Verti Inside width 70 cm depth 31cm 30 40417 Verti Inside width 80 cm depth 31cm 30 40418 Verti Inside width 90 cm depth 31cm 30 40419 Verti Inside width 100cm depth 31cm 30 40420 Material Welded steel pipes St 37 and various plastic components Surface treatment Blue chromate powder coating Power supply 230VAC 2 5A 50Hz Alternatively 100VAC 50 60 Hz Standby primary 0 3W Control v...

Page 5: ...and can move freely within the height adjustment range of the unit Travel 495mm The cupboard is mounted on the wall with min 530mm between the bottom of the cupboard and other installations for utilisation of the entire travel of the unit 703mm 350 450 550 650 750 850 950mm iincrementsval 495mm Depth 265mm or 310mm ...

Page 6: ...g of the control switch We recommend the installation of an empty conduit in the wall to accommodate the cable ø3 5cm If a high cabinet stands in the immediate vicinity of Verti Inside the cable may be run through the cabinet to avoid the conduit in the wall Max load 80kg evenly distributed over all three shelves for cabinets up to 100cm in width according to DS EN 12182 based on 8 screws bolts Mi...

Page 7: ...Page 7 ROPOX 2017 Cabinet height of 70 4 cm Cabinet height above 70 4 cm Fixed shelf for mounting the top safety stop electric installation electric installation ...

Page 8: ...eans of the control switch connected to the control unit The cupboard is adjusted upwards by pressing the UP symbol of the control switch and downwards by pressing the DOWN symbol of the control switch As soon as you let go of the control switch the movement of the unit will stop 5 1 4 Wiring diagram S2 S1 HS M1 ...

Page 9: ... must always be carried out by competent personnel Mount 2 x 30 40400 021 flush with rear edge of cupboard Remove back and bottom from the cupboard Note The back may remain in place if it is fastened to the wall by bolts Mount cupboard on wall Drill 1 x Ø40 hole in the top of the cupboard for cables Mark up for upper safety stop see 9 14 x Ø3 5x12 wood screw 1 2 3 4 70mm from center Wall ...

Page 10: ...rill holes in wall Fasten lifting unit 30 40400 042 with 7 screws Use screws and lplugs suiting the construction and materials of the wall 5 6 7 Mount suspension fixture 30 40400 103 on wall When installing the verti Inside in a cabinet height of 704 mm the safety stop will be 20mm lower than the cabinet 20mm ...

Page 11: ...xtension cord 93000162 Pull the cable behind the motor and through the hole at the top of the cupboard 2 Pull mains cable behind the motor and through the hole at the top of the cupboard connect and turn on power 3 Connect the motor cable 96000814 to M1 8 M1 HS Mains cable ...

Page 12: ...op Connect safety stop to control unit to the cable marked S1 See wiring diagram page 8 Mount upper safety stop on top of the cupboard Illustration shows cupboard viewed from below Wall 22mm 9 10 4 x Ø5x20 wood screw 4 x 96121409 plastic bushing ...

Page 13: ...85 The top of the cover plate has keyholes fitting the pre mounted bolts of the lifting unit The bottom of the cover plate has a flange fitting around the lifting unit When the keyhole and flange catch push the plate upward and tighten the bolts 11 ...

Page 14: ...Page 14 ROPOX 2017 12 Lift front plate into the cupboard and hook it onto the pre mounted bolts of the lifting unit Now mount the remaining 6 bolts 6 x M6x10 ...

Page 15: ...Page 15 ROPOX 2017 1 2 1 2 4 Connect safety stop and spiral cable ...

Page 16: ...Page 16 ROPOX 2017 Mount cable relief for mains cable on wall 13 ...

Page 17: ... ROPOX 2017 Mount 97701 841 and 97701 842 shielding for control switch 1 1 14 2 x M3x8 Place control switch acc to customer s wish and connect by means of cable 97000245 If required use extension cord 93000162 ...

Page 18: ... the power 2 Connect the motor cables to M1 3 Connect the control switch to HS 4 Press UP on the control switch move the frame to top position check that the movement is even and smooth The frame is now reset 5 Press DOWN on the control switch move the frame to buttom position and check that the movement is even and smooth The safety stops must be tested Lower safety stop Press the DOWN button and...

Page 19: ...ension cord for control switch 3 5m 1 one 98002087 Spiral cable male female 1 one 30 40400 113 40cm 30 40400 114 50cm 30 40400 115 60cm 30 40400 116 70cm 30 40400 117 80cm 30 40400 118 90cm 30 40400 119 100cm Front plate 1 one 30 40204 2 40cm 30 40205 2 50cm 30 40206 2 60cm 30 40207 2 70cm 30 40208 2 80cm 30 40209 2 90cm 30 40210 2 100cm Safety stop bottom for 26 5cm cupboard 1 one 30 40214 2 40cm...

Page 20: ...part 1 1 one 97701 842 Shielding for control switch part 2 1 one 9 Options Verti InsideElectric Split cable for control switch 96000629 1 one To be used if more than one control switch is required Infrared control 30 72006 1 function Remote control via infrared receiver cable 250 cm 1 one Infrared control 30 72007 2 functions Remote control via infrared receiver cable 250 cm 1 one Control switch l...

Page 21: ...or 70cm safety stop 2pcs 30 40448 Led for 80cm safety stop 2pcs 30 40449 Led for 90cm safety stop 2pcs 30 40450 Led for 100cm safety stop 2pcs For verti InsideElectric with debth 31cm 30 40454 Led for 40cm safety stop 1pc 30 40455 Led for 50cm safety stop 1pc 30 40456 Led for 60cm safety stop 1pc 30 40457 Led for 70cm safety stop 2pcs 30 40458 Led for 80cm safety stop 2pcs 30 40459 Led for 90cm sa...

Page 22: ...Page 22 ROPOX 2017 10 Placing of LED spot Verti InsideElectric with depth of 26 5cm Verti InsideElectric with depth of 31cm ...

Page 23: ...Page 23 ROPOX 2017 11 Cables for LED spot Spiral cable male femaleer is prepared for mounting of light For detailed instuctions see the folder that comes with the med LED spot ...

Page 24: ...rvation capacity may get near the unit the person operating the unit must pay attention to those present in order to prevent dangerous situations Make sure that there is free space above and below the unit to allow height adjustment Do not operate the unit in case of defects or damage Do not overload the unit and make sure that the load distribution is correct Do not use the unit in an explosive e...

Page 25: ... the frame Press the UP button and adjust the frame to top position Press the UP button once more and keep it depressed for 5 sec to reset the control unit Check that the movement is smooth and even Make sure that the mains cable moves freely Check that all cables have been mounted correctly and are undamaged After each inspection complete the service schedule Only use Ropox original spare parts f...

Page 26: ...ck that cables for safety stops are connected to control unit and safety stops 5 Check that safety stops have not been activated Reset procedure 6 If none of the above has helped reset the unit Remove all weight from Verti InsideElectric Disconnect motorcables Disconnect mains cable and wait 5 sec Connect mains cable Connect motor cable Move the unit to topposition for reset Service and maintenanc...

Page 27: ...he supplier It also contains information about the power supply to be used Symbols This manual must be read prior to use Waste must be sorted if possible for recycling Ropox is the manufacturer of the product in question CE marking This product meets the requirements for General Safety and Functionality of the current EU Directives and Standards Location of label ...

Page 28: ...ons with functional disabilities General requirements and test methods DS EN 14971 2012 Medical equipment The use of risk management in connection with medical equipment Risk analysis according to the Machinery Directive 2006 42 EC DS EN 9999 2011 Assistive devices for persons with functional disabilities Classification and terminology DS EN 60335 2012 Household and similar electrical appliances S...

Page 29: ...Page 29 ROPOX 2017 17 Complaints See General Terms of Sale and Delivery on www ropox dk ...

Reviews: