TF 200.01.0018_ENG 

3.4 Dimensions 

  

3.4.1 Without bed guard 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

3.4.2 With bed guard 

  

 

 

 

 

 

 

 

 

 

 

 

Model 

Length(L) 

40-30604 

120cm 

40-30606 

140cm 

40-30608 

160cm 

40-30610 

180cm 

40-30611 

190cm 

Model 

Length 

(L) 

40-30804 

120cm 

40-30806 

140cm 

40-30808 

160cm 

40-30810 

180cm 

40-30811 

190cm 

32cm 

11

5c

m

 

 

13cm 

Summary of Contents for Vario 40-30604

Page 1: ...Ropox Vario User manual This manual should always be in close proximity of the product TF 200 01 0018_ENG 26 07 2022...

Page 2: ...the lifting unit to the wall with screws at the top and bottom 14 4 4 2 Slide the front plate back into the lifting unit 15 4 4 3 Mount the cover plate on the top of the lifting 15 4 5 Mount the tabl...

Page 3: ...3 Mattress 24 11 Electromagnetic compatibility 25 11 1 Suitable Environments 25 11 2 Basic safety and Essential performance 25 11 3 Adjacent and stacked use 25 11 4 Cables 25 11 5 RF portable equipme...

Page 4: ...and handling of the product 2 General safety This manual must be read and understood before use Always keep this manual in close proximity of the product The use installation and service of this produ...

Page 5: ...has read and understood this manual The product is not intended to play with Do not use the product if it has defects or have become damaged before being repaired or replaced If the control box makes...

Page 6: ...Council Directive 2011 65 EU RoHS Manufacturer name and address Date of production Stock number Serial number Operating interval of electrically operated equipment The use of electrical height adjusta...

Page 7: ...Height adjustment 30 100cm Maximum user weight according to EN12182 2012 200kg Power supply 230V 50Hz I in Max 2 0A Intermittence 2min on 18min off IP rating IPX6 Ambient temperature 10 C to 50 C Tra...

Page 8: ...hanging bed is intended for use in private homes institutions day care centers and similar institutions and for people with physical or mental disabilities The product is designed to provide optimum w...

Page 9: ...4 1 Without bed guard 3 4 2 With bed guard Model Length L 40 30604 120cm 40 30606 140cm 40 30608 160cm 40 30610 180cm 40 30611 190cm Model Length L 40 30804 120cm 40 30806 140cm 40 30808 160cm 40 3081...

Page 10: ...ain power cable 230V has a total length of approx 320 cm of which 250 cm of the cable is outside the lifting unit The cable can be pulled out in either left or right side Caution When connected to the...

Page 11: ...later in this manual Then raise the sled to the top level position and use the cutout to ensure a safe fit of the electrical cable and cover with proper clearance all around It is crucial to control...

Page 12: ...parations 4 3 1 Dismount the top cover plate 4 3 2 Dismount the front plate Slide the front plate out of the Lifting unit to get access to the wall mounting holes in the unit Be aware not to bend or s...

Page 13: ...wall If the unit must be mounted on another kind of wall other kinds of plugs and screws must be used Changing bed has a max user weight of 200 kg Maximum load in the top screws is 40kg for each screw...

Page 14: ...14 TF 200 01 0018_ENG 4 4 1 Mount the lifting unit to the wall with screws at the top and bottom...

Page 15: ...15 TF 200 01 0018_ENG 4 4 2 Slide the front plate back into the lifting unit 4 4 3 Mount the cover plate on the top of the lifting...

Page 16: ...op on the lifting unit Slide the tabletop in between the Lifting unit and the support arms on the Lifting unit Fasten the tabletop to the Lifting unit with 4 pcs Screws M8x12 through the bushings in t...

Page 17: ...ned correctly before they are pushed into the sockets at the control box The plugs must be pushed into the sockets until the O ring is no longer visible Motor control box and control switch apply to I...

Page 18: ...he side of the box Caution To obtain the full IPX6 value it is very important that all the plugs have been pressed firmly into the sockets until the O ring is no longer visible 4 6 2 Placement of the...

Page 19: ...omise the product stability Special care should be taken in ensuring that no children or adults are sited under the product as severer injury from entrapment may occur Only adjust the product in heigh...

Page 20: ...d forth ensuring that the locking pin is fully engaged 5 1 3 How to fold changing bed up and down The worktop can be secured against inadvertent folding in upright position by locking the table with t...

Page 21: ...For unlocking folding worktop in downwards position remove pin Pin is placed in second hole for storage when shower bed is being used and folded down The worktop can now easily be folded up and down 5...

Page 22: ...afety 7 1 Periodic maintenance of bed guards If the product is used humid or dry atmosphere the locking pin may be prone to seizing from lubricants drying Besides checking the function of the locking...

Page 23: ...ctronics 9 Spare parts Name Part number 1 Control box CB6096 03 97000434 2 Actuator LA34 5 97000431 3 Motor cable L 300mm 97000423 4 230V cable 97000427 5 Ganter Pallet lock with axial protection 9517...

Page 24: ...7 1 L 160cm 180cm 190cm 1 Item number Size Pcs 40 25782 1 L 120cm 140cm 1 40 25783 1 L 160cm 180cm 190cm 1 Item number Size Thickness 40 25760 1 Madras L 120 cm w underlay 3 cm 40 25795 1 Madras L 140...

Page 25: ...acked with other equipment should be voided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are ope...

Page 26: ...00 01 0018_ENG 12 Complaints See our general terms of sale and delivery on www ropox com ROPOX A S Ringstedgade 221 DK 4700 N stved Phone 45 55 75 05 00 Fax 45 55 75 05 50 E mail info ropox dk www rop...