Controller functions
Page 28
RES-445
10.5
Menu steps
No.
Name
Description
Setting range
Home position
The specified set value and the current actual value
are displayed in digital form. The actual value is
also represented as a dynamic bar.
If time control (step 26) is active, the heatsealing
time and the cooling value are also displayed.
The heatsealing band can be heated manually (to
the specified heatsealing temperature) by pressing
the "HAND" key.
1
Heatsealing
temperature
The required heatsealing temperature (set point)
can be set with the "UP" and "DOWN" keys. The
maximum selectable set point can be limited with
step 22 (alloy/range) and step 23 (max.
temperature). If the heatsealing temperature is to
be determined by a voltage at the analog input at
terminals 20+23, it must be set to 0°C with this
menu step. The set point is indicated in the home
position.
If an external heatsealing temperature
(analog input, terminals 20+23) and an
internal heatsealing temperature (step 1) are
specified simultaneously, the higher of the two
temperatures is used and indicated in the main
menu.
Depends on setting of
step 22:
0, 40°C…maximum
temperature (step 23)
2
Preheating
temperature
The required preheating temperature can be set
with the "UP" and "DOWN" keys. The maximum
temperature (step 23) applies to both the
heatsealing temperature and the preheating
temperature.
The preheating function can be deactivated by
entering 0°C.
Depends on setting of
step 22:
0, 40°C…maximum
temperature (step 23)
3
Starting delay
This option allows the heatsealing time to be
preceded by a starting delay. This delay time
begins as soon as the start signal is applied. When
it elapses, the heatsealing time is activated.
This function can only be selected if time control
(step 26) is active.
0…9.9s
4
Heatsealing time
The length of the heatsealing pulse can be set with
the "UP" and "DOWN" keys. The specified
heatsealing time is indicated in the home position.
This function can only be selected if time control
(step 26) is active.
0…99.9s, EXT
!