Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4-5 ft 
(122-152.4 cm) long, 

¹⁄₂

" (1.3 cm) or 

³⁄₄

" (1.9 cm) I.D., flexible

metal appliance connector may be used for connecting range
to the gas supply line.

¹⁄₂

" (1.3 cm) male pipe thread is needed for connection to

the female pipe threads of the inlet to the appliance gas
pressure regulator.

Do not kink or damage the flexible metal tubing when moving
the range.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the range. The rigid pipe must
be level with the range connection. All strains must be removed
from the supply and fuel lines so range will be level and in line.

Must include a shutoff valve:

The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the range. It should be in a location that allows
ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the
range.

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be
used. The inlet pressure to the regulator should be as follows for
proper operation:

Natural Gas:

Minimum pressure: 5" WCP

Maximum pressure: 14" WCP

LP Gas:

Minimum pressure: 11" WCP

Maximum pressure: 14" WCP

Contact local gas supplier if you are not sure about the inlet
pressure.

A

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level.

Gas Supply Pressure Testing

Line pressure testing above 

¹⁄₂

psi gauge (14" WCP)

The range and its individual manual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures greater than 

¹⁄₂

psi (3.5 kPa).

Line pressure testing at 

¹⁄₂

psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of that system at test pressures equal to or less than 

¹⁄₂

psi (3.5 kPa).

B

C

A. Shutoff valve in “open” position
B. Gas supply line
C. To range

Summary of Contents for FGP305KW

Page 1: ...IMPORTANT Save for local electrical inspector s use INSTALLATION INSTRUCTIONS 30 76 2 CM FREESTANDING GAS RANGE with standard clean oven W10032070 Table of Contents 2...

Page 2: ...bol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean foll...

Page 3: ...and service must be performed by a qualified installer service agency or the gas supplier Do not use any phone in your building In the State of Massachusetts the following installation instructions ap...

Page 4: ...learances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical...

Page 5: ...lling a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface 5 Fo...

Page 6: ...rsonnel and authorized service personnel Failure to do so can result in death explosion or fire Electrical Requirements IMPORTANT The range must be electrically grounded in accordance with local codes...

Page 7: ...lve The valve is for turning on or shutting off gas to the range Gas Pressure Regulator The gas pressure regulator supplied with this range must be used The inlet pressure to the regulator should be a...

Page 8: ...econnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults Install Anti Tip Bracket Contact a qualified floor...

Page 9: ...r connection fitting B 90 elbow C Black iron pipe D Union E Nipple F Manual shutoff valve G to gas pipe B 8 Move the range close to the opening Remove the shipping base cardboard or hardboard from und...

Page 10: ...If the low flame needs adjusting 1 Turn control knob to the LO setting and remove control knob 2 Insert a small flat blade screwdriver into the valve stem Turn the valve adjusting screw to obtain the...

Page 11: ...on and check for proper flame If the flame is still not properly adjusted turn the oven off wait for the oven burner to cool down and repeat step 4 until flame is properly adjusted B C A A Oven tray l...

Page 12: ...ve a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized ser...

Page 13: ...d IMPORTANT Do not over tighten 6 Place natural gas oven burner spud in plastic parts bag along with natural gas cooktop burner spuds for future use and keep with bag containing literature 7 Reinstall...

Page 14: ...ect power 3 Open broiler door and remove broiler pan The gas pressure regulator is located in the back right hand corner of the broiler compartment IMPORTANT Do not remove the gas pressure regulator N...

Page 15: ...ts bag along with LP gas cooktop burner spuds for future use and keep with bag containing literature 7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 R...

Page 16: ...W10032070 2006 Whirlpool Corporation All rights reserved Printed in Mexico 07 2006...

Reviews: