INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Parts supplied

Check that all parts are included.

Anti-tip brackets must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.

Parts needed

Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT:

Observe all governing codes and ordinances. Do

not obstruct flow of combustion and ventilation air.

It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the oven frame behind
the left side of the broiler door.

The range should be located for convenient use in the
kitchen.

Recessed installations must provide complete enclosure of
the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.

All openings in the wall or floor where range is to be installed
must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip
Bracket” section.

Grounded electrical supply is required. See “Electrical
Requirements” section. 
Proper gas supply connection must be available. See “Gas
Supply Requirements” section.

Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).

Use an insulated pad or 

¹⁄₄

" (0.64 cm) plywood under range if

installing range over carpeting.

IMPORTANT:

Some cabinet and building materials are not

designed to withstand the heat produced by the oven for baking
and self-cleaning. Check with your builder or cabinet supplier to
make sure that the materials used will not discolor, delaminate or
sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.

Level

³⁄₈

" drive ratchet

Tape measure

Flat-blade screwdriver

Phillips screwdriver

Hand or electric drill

Slip-joint pliers

7 mm combination wrench

Pipe wrench

¹⁄₈

" (3.2 mm) drill bit (for wood floors)

³⁄₁₆

" (4.8 mm) carbide-tipped masonry drill bit 

(for concrete/ceramic floors)

Pipe joint compound resistant to LP gas

Non-corrosive leak-detection solution

B

A

C

A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x 1 1/2

screws (2)

Model/serial 
rating plate
location

Summary of Contents for FGP305KW

Page 1: ...IMPORTANT Save for local electrical inspector s use INSTALLATION INSTRUCTIONS 30 76 2 CM FREESTANDING GAS RANGE with standard clean oven W10032070 Table of Contents 2...

Page 2: ...bol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean foll...

Page 3: ...and service must be performed by a qualified installer service agency or the gas supplier Do not use any phone in your building In the State of Massachusetts the following installation instructions ap...

Page 4: ...learances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical...

Page 5: ...lling a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface 5 Fo...

Page 6: ...rsonnel and authorized service personnel Failure to do so can result in death explosion or fire Electrical Requirements IMPORTANT The range must be electrically grounded in accordance with local codes...

Page 7: ...lve The valve is for turning on or shutting off gas to the range Gas Pressure Regulator The gas pressure regulator supplied with this range must be used The inlet pressure to the regulator should be a...

Page 8: ...econnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults Install Anti Tip Bracket Contact a qualified floor...

Page 9: ...r connection fitting B 90 elbow C Black iron pipe D Union E Nipple F Manual shutoff valve G to gas pipe B 8 Move the range close to the opening Remove the shipping base cardboard or hardboard from und...

Page 10: ...If the low flame needs adjusting 1 Turn control knob to the LO setting and remove control knob 2 Insert a small flat blade screwdriver into the valve stem Turn the valve adjusting screw to obtain the...

Page 11: ...on and check for proper flame If the flame is still not properly adjusted turn the oven off wait for the oven burner to cool down and repeat step 4 until flame is properly adjusted B C A A Oven tray l...

Page 12: ...ve a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized ser...

Page 13: ...d IMPORTANT Do not over tighten 6 Place natural gas oven burner spud in plastic parts bag along with natural gas cooktop burner spuds for future use and keep with bag containing literature 7 Reinstall...

Page 14: ...ect power 3 Open broiler door and remove broiler pan The gas pressure regulator is located in the back right hand corner of the broiler compartment IMPORTANT Do not remove the gas pressure regulator N...

Page 15: ...ts bag along with LP gas cooktop burner spuds for future use and keep with bag containing literature 7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 R...

Page 16: ...W10032070 2006 Whirlpool Corporation All rights reserved Printed in Mexico 07 2006...

Reviews: