FIRST OPERATION

V5.4 LA

1 . On Power up- 

Shows the software  version (V5.4) & 

set battery type when switched On (while booting)

0016:10

2  .  On  Start  Up- 

On  start  up  it  displays  the  total 

previously  run  hours  of  the  machine-Format  - 
hhhh:mm and battery voltage tower.

0016:10

3 . Brush Motor ON- 

A brush symbol is displayed when 

the brush motor is  switched ON.

0016:10

4 . Suction Turbine ON- 

A turbine symbol is displayed 

when the suction turbine is switched On.

DISPLAY LAYOUT OF LCD

00 16:10

5 . 

For B 6060 - 

Brush Motor & Suction Turbine 

OFF-  The brush motor shuts down immediately 
when switch “B” is pressed but when switch “C” 
is pressed the suction turbine shuts down after 
a delay of 15 seconds.

5 . 

For B 6060x

 

-

 Brush Motor & Suction Turbine 

OFF-  The brush motor shuts down immediately 
when switch “C” is pressed but when switch “D” 
is pressed the suction turbine shuts down after 
a delay of 15 seconds.

0016:10

6  .  The  brush  motor  &  suction  turbine  icons  will 

start flashing just before the battery cut off level.

0016:10

7 . 

For B 6060x - 

Solenoid valve ON- 

A tap symbol is 

displayed when the s

olenoid valve

 is  switched ON.

0016:10

8 . Fully discharged condition.

Summary of Contents for RootsScrub B6060

Page 1: ...tsScrub B6060 B6060x Owner s Manual RootsScrub B6060 B6060x Walk Behind Floor Scrubber Drier Battery Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion...

Page 2: ...2 RootsScrub B6060 B6060x...

Page 3: ...tructions First Operation Operation Brush Operation Squeegee Procedure for Scrubbing Maintenance Battery Instructions 4 5 5 6 8 11 12 13 15 17 Description Page No Roots Multiclean Ltd RMCL is not liab...

Page 4: ...product sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ens...

Page 5: ...rking Speed up to km h 4 4 Battery Rating V Ah 12 96 Airflow rate L sec 28 28 Vacuum Pressure mm of H2O 1087 1087 Power Supply V 24 24 Total Power W 1000 1000 Brush Motor W 720 720 Vacuum Motor power...

Page 6: ...manual Protect the machine from frost or extremely low temperatures Never vacuum up explosive liquids combustible explosive dusts as well as acids and solvents This includes diesel petrol kerosene pai...

Page 7: ...hat there is adequate ventilation for diverting the exhaust gases dust when operating the machine in a closed area Do not place hand or any object while the brushes are running Suitable tools must be...

Page 8: ...e same cycle through the squeegee Thus the floor can be walked on immediately after it is dry and clean 2 3 4 1 Useful Tips Prior to wet cleaning it is necessary to sweep the floor This way not only i...

Page 9: ...or On Off Shows information software version D set battery and type battery charging and status brush motor suction turbine On Off total hours run E LED Glows Green when power is On Display A Before O...

Page 10: ...LAY LAYOUT OF LCD 00 16 10 5 For B 6060 Brush Motor Suction Turbine OFF The brush motor shuts down immediately when switch B is pressed but when switch C is pressed the suction turbine shuts down afte...

Page 11: ...outside unlock and then allow it to move slowly upwards For lifting press the pedal slowly downwards and make it lock Brushes Pads The machine must be equipped with brushes from the accessories kit a...

Page 12: ...rips 2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Lift squeegee bracket group...

Page 13: ...rder to preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adopted to the machine These products fulfil the requirements of the cleaning solution...

Page 14: ...or draining tanks Unclamp the drain hose from the hose clamp Lower the tip of the drain hose to the floor level After draining the water completely clamp the hose in the hose clamp Cleaning of floor a...

Page 15: ...you the certitude always having a machine at your disposal which is ready to work and in good operating condition Daily Every 50 Every 100 Every 200 Check connection extension cables and plugs for goo...

Page 16: ...Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not work Faulty suction...

Page 17: ...tilated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly corrosi...

Page 18: ...connections and bolted terminals tight and covered with petroleum jelly Keep the machine tank opened while charging to improve ventilation Battery and Charger Batteries connecting diagram The batteri...