background image

   

 

 

   

 

Summary of Contents for ACCURA 2350-TEMPS

Page 1: ......

Page 2: ...at have received appropriate training for high voltage and current devices Caution If hazardous voltages are mishandled while installing and operating the product in the field it can cause serious injury or death This device must be installed and serviced only by qualified personnel who have in depth knowledge of installing commissioning and operating the device and have had appropriate training H...

Page 3: ...cations and the manual before making orders In the absence of written agreements Rootech Inc assumes no liability for applications assistance customer s system design or infringement of patents or copyrights induced by third parties arising from the use of the products described herein We endeavor to provide accurate information in the document However we are not responsible for any errors which m...

Page 4: ... refund for the product for when the warranty period for the product expired or issues related to the product are not applicable for warranty terms and conditions Limitation of Warranty The Warranty does not apply to uninterrupted or error free operation of the product or cover normal wear and tear of the product or costs caused by the removal installation or troubleshooting of the customer s elec...

Page 5: ...conduct tests to prove their feasibility It is the original purchaser s responsibility to determine the suitability of the product and associated documentation The original purchaser should acknowledge that 100 up time is not realizable because of possible hardware or software defects The original purchaser should recognize that such defects and failures may cause inaccuracies or malfunctions No a...

Page 6: ...t on events and added remote control settings 1 12 November 11 2014 Added content on environmental conditions including temperature and humidity Updated event display options 1 20 December 18 2014 Added the Notice Warranty and Contents sections Added the communication setup section 1 21 June 10 2020 Updated standards and changed the device name 1 22 February 8 2022 Changed the image and text on th...

Page 7: ...ernal External Temperature Measurement 13 Temperature Event 13 Display Mode 14 Automatic Display 14 Internal Temperature Display IN Inside 15 External Temperature Display OUT Outside 15 EVENT Mode 15 Button Operation 15 Maximum Temperature Display MaX Maximum PPM 16 Setup Mode 16 Button Operation 16 Communication Setup 21 Chapter 3 Accura 2300 S Operation Setup 22 Display Mode of Accura 2300 S 22 ...

Page 8: ...LED reset with the SET button after the event ends 20 Fig 2 3 Operation of Event LED reset with the SET button before the event ends 20 Fig 3 1 Internal Temperature 23 Fig 3 2 External Temperature 23 Fig 3 3 DO Operation Setup Screen of Accura 2300 S 24 Fig 3 4 Start Event on Internal Temperature 24 Fig 3 5 End Event on Internal Temperature 24 Fig 3 6 Start Event on External Temperature 25 Fig 3 7...

Page 9: ...nc All Rights Reserved Page 9 Chapter 1 Installation and Wiring Before Installation Components Fig 1 1 Accura 2350 TEMPS Components Accura 2350 TEMPS RJ12 6C communication line Dimensions Fig 1 2 Accura 2350 TEMPS Front Fig 1 3 Accura 2350 TEMPS Rear Fig 1 4 Accura 2350 TEMPS Side ...

Page 10: ...l It is easy to mount it on the panel Fit the Accura 2350 TEMPS module into the panel cutout Fit the mounting wheel on the front of the module Fix the module onto the panel by turning the mounting wheel The wheel can be easily fastened to the module by using your hands If you put excessive force using extra tools to turn the wheel it can cause damage to the Accura 2350 TEMPS module Fig 1 5 Panel M...

Page 11: ...20 Rootech Inc All Rights Reserved Page 11 Communication Cable Connection Connect the RJ12 6C communication line to the RJ12A RJ12B port Accura 2350 TEMPS module receives power from Accura 2300 S via the RJ12 6C communication line Fig 1 6 Communication Cable Connection ...

Page 12: ...ly LED Status Indicators LEDs are on the right and left sides of the Accura 2350 TEMPS module and indicate the power supply and event status of the module LED Indicator Green LED turned on power supply status Displays the power supply status of Accura 2350 TEMPS module Red LED blinks event status Displays the status in which an event occurs The event LED can be reset by long pressing the button No...

Page 13: ...ture measurement of the panel Measuring range 20 to 100 Measurement accuracy 2 FS 1 20 to 100 Temperature event Internal temperature Detects the occurrence of an Over temperature event 2 based on the threshold value for the internal temperature event External temperature Detects the occurrence of an Over temperature event 2 based on the threshold value for the external temperature event Difference...

Page 14: ...ent detection it can cause multiple events to occur Thus for effective event management it is necessary to set up a proper hysteresis level The default hysteresis value for each event is 1 and it can be set up via communication Display Mode Automatic Display Accura 2350 TEMPS module automatically displays the module ID and the internal external temperature of the panel where it is installed in the...

Page 15: ...e unit of temperature measurement is set to Celsius EVENT Mode The screen automatically switches to the event mode when an event occurs In the event mode the location data of the temperature sensor and the maximum temperature blink The event mode can be reset by long pressing the SET button The LED on the front of the module blinks red in the event mode In the display mode the LED turns green to n...

Page 16: ...1 Move to the setup mode The setup menu is sequentially selected each time the SET button is pressed Long press 2 The preset value blinks and can be changed Short press Select a preset value to change by pressing the button The setup value changes sequentially each time the button is pressed Long press Save the selected setup value And then the screen stops blinking Move to the next setup menu 1 P...

Page 17: ...tory default value Accura 2350 ID ID Description Communication ID ID 0 39 ID of the module that enables communication Conflict ID Redundant IDs There are more than 2 identical IDs communication unavailable Standby ID ID 255 Module ID for checking connection status communication unavailable Temperature Unit Setup o C Celsius o F Fahrenheit Setup Description oC default Celsius o F Fahrenheit Setup f...

Page 18: ...ue rises above the threshold value for event detection 1 An over event consists of a start event and an end event Threshold Setup for Internal External Temperature Event Io Inside Outside t Threshold The screen displays the setup item and value in sequence If the SET button is pressed to change the value only the value blinks on the screen The same threshold value is used for the detection of inte...

Page 19: ...creen displays the setup item and value in sequence If the SET button is pressed to change the value only the value blinks on the screen Setup on default On Remote device setup and control via communication is enabled oFF Off Remote device setup and control via communication is disabled If the remote control function is set to On in the Accura 2350 TEMPS module the event LED can be reset by pressi...

Page 20: ...T button after the event ends Threshold Temperature start event end event with hysteresis Temp Over Start Event End Event Button Clear LED green red color Fig 2 3 Operation of Event LED reset with the SET button before the event ends Threshold with hysteresis Temp Over Start Event End Event Button Clear LED Temperature start event end event start event green red color ...

Page 21: ...cated as 1 By writing 1 to this register data on registers 1263 1302 are applied to the designated module 1263 Temperature unit Uint16 PRW Sets up the temperature display unit 0 default 1 1264 Event enable Uint16 PRW Sets up event detection mode Bit 0 Internal overtemperature event 0 default Disable 1 Enable Bit 2 External overtemperature event 0 default Disable 1 Enable Bit 4 Over event on temper...

Page 22: ...ems but the display segments of Accura 2300 are slightly different from those of Accura 2300S Mode Description Display mode Displays the measured values of the selected Accura 2350 module ID Setup mode Supports setup for various parameters of Accura 2300 S 2350 modules network wiring PT communication event etc Event log mode Displays the event log on dips and swells Display Mode of Accura 2300 S F...

Page 23: ...2 External Temperature Event Alarms on Accura 2300 S Accura 2300 S detects events of the Accura 2350 TEMPS module When an event occurs the EVENT LED on Accura 2300 S blinks and the color of the LCD backlight changes from white to red to notify users of the occurrence of the event Users can enter the event log mode by long pressing the EVENT button on Accura 2300 S and can check the event log and c...

Page 24: ...n reset the output status in the event log mode by long pressing the EVENT button on Accura 2300 S In the event log mode users can check event data and can also clear the event alarm and DO signals Fig 3 3 DO Operation Setup Screen of Accura 2300 S Setup for Accura 2350 TEMPS Module Setting the Accura 2350 TEMPS module with the button on Accura 2300 S is not supported Users can set up Accura 2350 ...

Page 25: ...ays the module type Accura 2350 TEMPS 3rd row Displays the event type Internal External Difference Start event End event 4th row For the start event the number indicates the measured temperature when a start event is detected For the end event the number indicates the maximum temperature measured during the event interval Users can check the event occurrence time year month day hour minute second ...

Page 26: ...between internal external temperatures Over event 2 where the difference between internal and external temperatures rises above the set threshold 1 Full Scale FS indicates 100 C 2 An Over event refers to the event that occurs when the measured temperature rises above the set threshold The Over event consists of a start event and an end event Power Supply Description Power supply Receives power fro...

Page 27: ...Accura 2350 TEMPS User Guide Appendix B Ordering Information ⓒ 2020 Rootech Inc All Rights Reserved Page 27 Appendix B Ordering Information Model Name Accura 2350 TEMPS ...

Page 28: ...500 are trademarks of Rootech Inc Contact us for detailed product specifications and ordering information Information contained herein is subject to change without notice CopyrightⓒRootech Inc Printed In Korea Rootech Inc 102 611 Digital Empire 2 Sinwon ro 88 Yeongtong gu Suwon Gyeonggi do Korea Tel 82 31 695 7350 Fax 82 31 695 7399 Contact us for technical support and purchasing inquiries www roo...