background image

8

ASSEMBLY INSTRUCTIONS

4.)

 Connecting the Socket

Coat the gas supply pipe nipple with gas approved pipe compound or tape. Screw 

the quick connect socket included with your fire table onto the gas supply pipe.

The quick disconnect should not be permanently attached to the gas hose on the fire 

table. The direction of the gas flow is indicated on the socket.

5.)

 Using the Quick Connect Socket

Using one hand, pull back the sleeve on the quick connect socket and, with the other 

hand, insert the unattached end of the fire table gas hose into the socket. Release the 

sleeve and continue pushing the hose into the socket until the sleeve snaps into the 

locked position.

After making the connection, perform a leak check as described on the next page.

Apply gas approved, pipe 

compound or tape

Professionally installed shut-off 

valve on the gas supply line

Screw the provided quick connect 

socket onto the gas supply pipe

From Fire 

Table

Summary of Contents for 1112NG-TGR

Page 1: ...s in the vicinity of this or any other appliance An LP cylinder not connected for use should not be stored in the vicinity of this or any other appliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment 170919FTNG 171130 776074 ...

Page 2: ...ch as a camper tent car or home Product Name Adara Rectangle Fire Table Model No 1112NG Rated Heat Output 65 000 BTUs hr Type of Gas Natural Gas NG Gas Supply Professionaly Installed NG system Important Safety Information Parts List Assembly Instructions Pre Use Instructions Lighting Instructions Care and Cleaning Spider and Insect Warning Tips Troubleshooting Technical Parts List Warranty 3 5 6 9...

Page 3: ...ble Do not place the fire table on anything that blocks or seals the gap between the table and the ground Do not permanently secure the fire table in any way or to any surfaces Do not bury the hose You must be able to visually inspect the hose for damage before each use Do not coil or hide the hose under the fire table The hose could be damaged if it touches hot surfaces Children and adults should...

Page 4: ...ys where people may trip over it Do not place the hose in areas where it may be accidentally damaged Before each use examine the burner and its components for dirt and debris If cleaning is required use a pipe brush and soapy water solution Also examine the area around the burner Any dirt or foreign material such as spider webs nests leaves etc should be removed If it is evident that the burner is...

Page 5: ... B Number JCo NUMBER QUANTITY Fire Table Body N A N A 1 Lid N A 11122005 1 NG Hose and N A 056NG010 1 Quick Connect Socket Black Lava Rock 970274 100240120J 1 Protective Cover 869214 11120002 1 Valve Key 711797 11110004 1 1 2 3 4 5 6 ...

Page 6: ......

Page 7: ...e s gas system is capable of providing the correct amount of gas at the correct pressure for your ire table to operate safely and correctly The socket connection must be made outdoors The diagram below shows the main components of a standard natural gas connection If the socket connection is below the fire table no part of the hose may contact the side panels or base panel of the burner area when ...

Page 8: ...g the Quick Connect Socket Using one hand pull back the sleeve on the quick connect socket and with the other hand insert the unattached end of the fire table gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After making the connection perform a leak check as described on the next page Apply gas approved pipe ...

Page 9: ... table to the gas supply line Spray leak solution on the valve connections paying particular attention to the areas indicated in the diagrams below by arrows If bubbles appear shut off the gas supply disconnect the hose and inspect all connections making sure threads are clear of debris Reconnect the hose turn the gas supply on and re test If you continue to see bubbles turn the gas supply off dis...

Page 10: ...bserve the flame and make sure that all the burn ports are lit 7 Adjust the flame to the desired height using the key valve 8 WARNING If ignition does not occur in 15 seconds turn the key valve to the OFF position and turn the gas off at the tank Make sure there is no source of ignition around the fire table and wait at least five minutes until the gas has cleared to repeat the lighting procedure ...

Page 11: ...ire table Burner The burner should be kept clean to ensure proper operation Clogged burn ports may be cleared with a paper clip or pin Debris in the burner can be cleaned using compressed air or a pipe brush Soot After use it is possible for soot to develop on some surfaces this soot deposit will usually come off with water and mild soap 1 Turn the gas supply off at shut off valve Disconnect the q...

Page 12: ...ruct or block the flow of gas Some of the gas may back up in the burn tube and cause a flashback a fire in the burn tube or underneath the fire table which could result in personal injury or property damage Check and clean the burn tube periodically using a pipe cleaner brush as shown below available at any hardware store and compressed air Insect Nest Possible Spider Nest or Debris ...

Page 13: ...r Common Problems Clogged or Obstructed Burner It is common for bugs especially spiders to make webs or nests inside of burner tubes If it seems like you are getting low or no gas flow visually check all openings in the burner for signs of clogs If you see anything clogging the burner try using compressed air to remove the debris High Winds High winds may cause the flame to blow out Do not operate...

Page 14: ...14 TECHNICAL PARTS LIST NG Hose and Quick Connect 056NG010 Burner Kit Key 11110004 Rectangle Lid 11122005 Thumb Screw 11110006 Foot x 4 115010003 Protective Cover 11120002 Lava Rock 100240120J ...

Page 15: ...ceipt Replacement parts are not available for all units and only given at Real Flame s discretion We will assess any damage and find a solution which could include shipping you a replacement No replacements are available for discontinued items or repackaged open box products Please call Real Flame Customer Service at 800 654 1704 for replacement parts before returning the damaged item Please have ...

Page 16: ...idos inflamables en las cercanías de este o de cualquier otro artefacto Un cilindro de LP no conectado para el uso no debe ser almacenado cerca de este o de cualquier otro artefacto La instalación ajuste alteración servicio o mantenimiento incorrectos pueden causar lesiones o daños a la propiedad Lea atentamente las instrucciones de instalación operación y mantenimiento antes de instalar o reparar...

Page 17: ...SPECIFICACIONES PELIGRO DE MONÓXIDO DE CARBONO Este artefacto puede producir monóxido de carbono que no tiene olor Usarlo en un espacio cerrado puede poner la vida en peligro Nunca utilice este artefacto en un espacio cerrado como un campamento tienda automóvil o el hogar Nombre del producto Fogón Adara Nro de modelo 1112NG Salida de calor nominal 65 000 btu hr Tipo de gas Gas natural GN Alimentac...

Page 18: ...ue bloquee o obstruya el espacio entre el fogón y el suelo No fije de forma permanente el fogón de ninguna manera ni a ninguna superficie No entierre la manguera Debe ser capaz de inspeccionar visualmente la manguera para verificar la existencia de daños antes de cada uso No enrolle ni oculte la manguera debajo del fogón La manguera podría dañarse si toca superficies calientes Niños y adultos debe...

Page 19: ...eas donde pueda sufrir daños accidentales Antes de cada uso examine el quemador y sus componentes para comprobar la existencia de suciedad y residuos Si se requiere limpieza utilice un cepillo de tuberías y una solución de agua y jabón Examine también el área alrededor del quemador Cualquier suciedad o material extraño como por ejemplo telas de araña nidos u hojas debe ser removido Si es evidente ...

Page 20: ... B NUMÉRO JCo CANTIDAD Cuerpo del fogón N D N D 1 Tapa N D 11122005 1 Manguera de GN y N D 056NG010 1 conector de conexión Roca de lava negra 970274 100240120J 1 Cobertura de protección 869214 11120002 1 Llave de válvula 711797 11110004 1 1 2 3 4 5 6 ...

Page 21: ...a de relleno de vidrio Advertencia de material de relleno 1 No llene excesivamente el área del quemador con relleno de rocas o vidrio utilice sólo la cantidad especificada La profundidad total del relleno no debe ser de más de media pulgada por encima del tubo del quemador Sólo los productos de relleno Real Flame han sido certificados y probados para su uso seguro con este fogón El uso de otros ma...

Page 22: ... la cantidad correcta de gas a la presión correcta para el fogón para poder operarlo con seguridad y correctamente La conexión se debe realizar al aire libre El diagrama a continuación muestra los componentes principales de una conexión estándar de gas natural Si la conexión se encuentra por debajo del fogón ninguna parte de la manguera puede entrar en contacto con los paneles laterales o el panel...

Page 23: ...ida Utilizando una mano tire hacia atrás del mango del conector de desconexión rápida y con la otra mano inserte el extremo no conectado de la manguera de gas del fogón en el conector Suelte el mango y continúe presionando la manguera en el conector hasta que el mango encaje en la posición bloqueada Después de realizar la conexión realice una comprobación de fugas como se describe en la página sig...

Page 24: ...Rocíe la solución jabonosa en las conexiones de la válvula prestando especial atención a las áreas indicadas por las flechas y los diagramas a continuación Si aparecen burbujas cierre el suministro de gas desconecte la manguera e inspeccione todas las conexiones asegurándose de que las roscas de encuentran libres de residuos Vuelva a conectar la manguera abra el suministro de gas y vuelva a probar...

Page 25: ...llama asegúrese de que todos los puertos del quemador estén encendidos 7 Ajuste la llama a la intensidad deseada mediante la válvula llave 8 ADVERTENCIA Si el encendido no se realiza en 15 segundos gire la llave de la válvula a la posición CERRADO y desconecte el gas en el tanque Asegúrese de que no existe una fuente de ignición alrededor del fogón y espere al menos cinco minutos hasta que el gas ...

Page 26: ...os ya que los mismos dañarán el fogón Quemador El quemador se debe mantener limpio para asegurar el funcionamiento correcto Los puertos del quemador obstruidos pueden limpiarse con un clip o con un pasador Los residuos en el quemador se pueden limpiar con aire comprimido o un cepillo de tuberías Hollín Después del uso es posible que se acumule hollín en algunas superficies ese depósito de hollín g...

Page 27: ...de retroceder hacia el tubo de combustión y provocar un llamarada de retroceso fuego en el tubo de combustión o debajo del fogón lo que podría producir lesiones personales o daños a la propiedad Compruebe y limpie el tubo de quemado periódicamente usando un cepillo de limpieza de tuberías como se muestra a continuación disponible en cualquier ferretería y de ser posible con aire comprimido Nidos d...

Page 28: ...mas comunes Quemador obstruido Es común que insectos especialmente arañas tejan redes o nidos dentro de los tubos del quemador Si parece que está recibiendo poco o ningún flujo de gas revise visualmente todas las aberturas en el quemador para detectar señales de obstrucción Si percibe que algo obstruye el quemador intente usar aire comprimido para eliminar dichos residuos Vientos fuertes Los vient...

Page 29: ...S Manguera de GN y conector de desconexión 056NG010 Juego de quemadores Llave 11110004 Tuerca de acople 1111 20 Tapa 11122005 Tornillo mariposa 11110006 Pies x 4 115010003 Cobertura de protecció 11120002 Roca de lava 100240120J ...

Page 30: ...s piezas de repuesto no están disponibles para todas las unidades y sólo se ofrecen a discreción de Real Flame Evaluaremos cualquier daño y encontraremos una solución que podría incluir el envío de un reemplazo No hay reemplazos disponibles para productos discontinuados o productos reembalados caja abierta Llame al Servicio de Atención al Cliente de Real Flame al 800 654 1704 para obtener las piez...

Reviews: