APEX Ridge Side Row Installation
9
The end clamp must be un-
tighten and rotated 180
degrees to fix the panels.
Bottom bracket and pillar
shall be installed same as
other clamps.
Option (see illustration)
: By
rotating the base 180
°
(R
on bottom right) as shown
on Pg. 25 of Manual, there is
no need to rotate the top
clamp.
IMPORTANT!!
Slide End clamp toward to
PV Panel frame. And tighten
Side bolt to fix base and clamp.
Tighten End clamp and PV panel.
Tighten the end clamp to 142in-
lbs (16N.m) or 159.31in-lbs
(18N.m)
End clamp installation
Height adjustment
shall be done after
panels are fixed.
Note;
End Splice clamp shall be
installed same as regular End
clamp. Change the side of the
clamp and install as instructed
above. (seen eaves side row)
R