18 GAUGE 55MM BRAD NAILER
10
MAINTENANCE CHART & OPERATOR TROUBLESHOOTING
.
MAINTENANCE CHART
.
OPERATOR TROUBLESHOOTING
Practice
Reason
Method
Drain air line filter daily
Prevent accumulation of
moisture and dirt.
Open manual petcock.
Keep lubricator filled.
Keep the tool lubricated
Fill with RONIX
SERVICE pneu-
matic tool lubricant.
Clean magazine and feeder
mechanism.
Prevent a jam & Dry fire. Blow clean daily.
Lubricate the Tool after nailing. Extend the tool life.
Supply 3~4 drops of lubricant into
the tool.
Drain air compressor.
Keep the tool operated
properly.
Open petcock on air compressor
tank.
Problem
Check Method
Correction
Tool operates, but
no nail is driven.
Check air pressure.
Reduce air pressure. (58~100psi)
Check for a jam.
Clean a jam. (Refer to 4-1)
Check for proper nail.
Use only recommended nails.
Tool operates, but
no nail is driven.
Check air line & Plug
Check for air line connection and dam-
age to fitting part (Change it in case of
damage)
Check for abnormality in head
valve
Change O-ring in case of damage
Check air pressure.
Reduce air pressure. (58~100psi)
Check position Piston set
Readjust.
-
Supply of lubricant into the tool.
Driver blade worn or damaged?
Part change (Contact RONIX
SERVICE
or Distributor)
Piston O-ring worn or damaged?
-
Check air pressure.
Reduce air pressure. (58~100psi)
Check air pressure.
Reduce air pressure. (58~100psi)
Check for proper nail.
Use only recommended nails.
-
Supply of lubricant into the tool.
Piston O-ring cut or heavily worn?
Part change. (Contact RONIX SERVICE
or Distributor)
Check air pressure.
Reduce air pressure. (58~100psi)
Check inside diameter of air hose. Use larger air hose.