RH560WIRELESS CMS OPERATION MANUAL
Page 8/15
Fixation though holder
:
b.
Antenna installation
:
Install the HG
‐
2404U gray antenna in RF port, connection type is N.
c.
System connection
:
The power supply is go through the PWR port from RH560
‐
WL bottom, and fixed with PG
screw.
【
Notice
】:
If RH560
‐
WL is installed outdoor, the lightning protection device should be
installed additionally.
【
Notice
】:
The socket head cap screw and PG screw should be fixed well.
4.4.2
RH505 Installation
RH505 is fixed through M6 screw and magnet base on the surface of machines, the torque
of RH505 is 8N.
【
Notice
】:
Before install the magnet base, please clean the measuring point position, greasy
dirt or dust is not allowed.
【
Notice
】:
RH505 should be fixed after the glue is solidified completely.
【
Notice
】:
The cover of RH505 should be fixed well.
【
Warning
】
:
If the installation is improper, it will cause incorrect data diagnostic conclusion.
4.4.3
RH509 Installation
RH509 shall be fixed on the machine surface through holder by two screws, the holder can be
fixed by screws on the equipment. RH509 speed sensor is a kind of eddy current sensor, it use
hose clamp for triggering, the hose clamp is installed on the rotating shaft.