background image

RH560WIRELESS CMS OPERATION MANUAL

Page 14/15

7. Product maintenance and fault elimination

7.1

Maintenance

We suggest to have dust elimination, anti

corrosion inspection and other operations every 3

months. If the equipment is not be used for long time, please power off and keep it in dry and no
corrosive gas environment.

7.2

Fault analysis and elimination

When there is problem with the equipment, please check it according to the following table,

if the problem still can’t be solved, please contact technical department of RONDS company.

Fault type

Possible reason

solution

RH560

WL RUN LED is not

light

Power disconnected or switched
off

Check power supply and switch

Normal communication but
now data collector
displayed in online service

RH560

WL or server IP setting is

not associated with each other

Check configuration info.

All sensors have no data

RH560

WL

disconnected

with

server

Check RH560

WL power supply and

configuration info.

Some sensors have no data

RH505 switched off or error
configuration info.

Check

RH505

switch,

PANID,

frequency band and IP info.

Some sensors data is not
correct

Low battery voltage of RH505

Check battery condition from online
service

FCC STATEMENT :

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.

Warning:

Changes or modifications not expressly approved by the party responsible for

compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or

Summary of Contents for RH560-WL

Page 1: ...RH560WIRELESS CMS OPERATION MANUAL 第 1 页 共 15 页 RH560 WL Wireless CMS User Manual ANHUI RONG ZHI RI XIN INFORMATION TECHNOLOGY CO LTD 2016 03 ...

Page 2: ... 6 4 2 Out of box audit 6 4 3 Installation announcements 7 4 4 Installation 7 4 4 1 RH560 WL Installation 7 4 4 2 RH505 Installation 8 4 4 3 RH509 Installation 8 4 5 Announcement for the first time using 9 5 Equipment operating 9 5 1 Summarize 9 5 2 Announcements 9 5 3 RH560 WL Switch and LED description 9 6 Software user manual 10 6 1 Summarize 10 6 2 User login 10 6 3 Software configuration 11 6...

Page 3: ...might be occurred if there is improper operating 2 Product introduction 2 1 Summarize 1 RH560 WL WIRELESS CMS is positioned on industrial enterprises which is developed by RONDS Company for scattered measuring points and unavailable wiring work It integrates vibration temperature and speed signals 2 System hardware includes RH560 WL wireless collection station RH505 wireless vibration temperature ...

Page 4: ...er MOS3000 support for multiple DAQ parameter sending 2 Wireless collection station will update the DAQ parameter after receiving from MOS3000 software 3 RH505 and RH509 sensor will receive DAQ parameters after power on and then collect data accordingly these data shall be sent to RH560 WL wireless collection station through Zigbee 4 RH560 WL wireless collection station receives data from every wi...

Page 5: ... of both constant and variable speed rotating machines Low consumption design IP66 protection degree EXIA intrinsic safety certified can be sued for special industries like petrochemical and mining field Internal antenna more reliable in industrial field 2 5 Technical specifications RH560 WL Wireless data collector Input and output Communication with Sensor 2 4GHz IEEE 802 15 4 Indicator LED Total...

Page 6: ...onal training is not allowed to disassemble and repair this equipment RONDS is not responsible for the accidents that caused by this kind of operating Correctly configure parameter with products and connect power supply Make sure there is earth wiring for power supply and check the reliability Please contact with RONDS if any problems Notice Please contact RONDS company if any questions or suggest...

Page 7: ...al training Danger Please make sure the security when using 220V power supply in case of any human injury Danger When install sensors on the surface of the machine please make sure the machine is stopped 4 4 Installation 4 4 1 RH560 WL Installation a Fixing method RH560 WL has two methods of fixing Hanging and fixation though holder Users can choose one of them according to the actual situation Th...

Page 8: ...h M6 screw and magnet base on the surface of machines the torque of RH505 is 8N Notice Before install the magnet base please clean the measuring point position greasy dirt or dust is not allowed Notice RH505 should be fixed after the glue is solidified completely Notice The cover of RH505 should be fixed well Warning If the installation is improper it will cause incorrect data diagnostic conclusio...

Page 9: ...s for basic skills of the operators in order to ensure safe correct and efficient using of this equipment please read this manual carefully before operating 5 2 Announcements After installation and configuration please pay attention to the following Check the connection of power supply and earth wiring Check each component parameter setting Check the equipment fixing Make sure the working environm...

Page 10: ...software is monitor the data collected by RH560 WL then provide detailed data analysis information Please install SQL database and MOS3000 online monitoring software at the same time MOS3000 will generate 3 programs MOS3000 Online monitoring system MOS3000 System configuration tool and Online service Notice When configure parameter of MOS3000 System configuration tool and online service please mak...

Page 11: ... be a tick mark 6 3 Software configuration 1 Choose System configuration right click Root to create Organization Machine Measuring point and DAQ definition The information of Organization Machine and Measuring point can be edited RH560 WL system support for 3 measurement definition maximally data length and Fmax can reach to 256K and 20KHz respectively ...

Page 12: ...ype RH560 WL 2 Server name choose the right database to store data or create new database in the popup windows 3 Collection station code input the last four number 4 Collection method variable speed or constant speed test mode is forbidden 5 Monitoring machine click it to add relative machines 6 Associate measuring point ...

Page 13: ...d information please refer to MOS3000 Online monitoring software user manual 6 5 Software abnormal processing 1 Can t login software a please check the SQL database and local server is working normally or not b Please check the online service and configuration service is started or not 2 Failed to send DAQ definition Please check if the data collector is displayed in the online service 3 No collec...

Page 14: ...data is not correct Low battery voltage of RH505 Check battery condition from online service FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modific...

Page 15: ...ipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body ...

Reviews: