background image

DOMVT 

Version:1.1 

Creator: 5167 Validator: 5160

June 2020

X30

General Instructions

Removing the setting stem can only 

be effected in Pos. I.

The use of supporting screws is 

essential when mounting the hands.

Permitted hand setting strengths:
Hr / min. hands: 

<40N

Second hand: 

<30N

During quick date correction 

(setting stem in position II), a date 

switching speed of 5 d/s must not 

be exceeded.
The following lube points have to be 

applied to the winding stems during 

casing:

T2 instructions

R150

Fitting dial and hands

• Crown in position III

• Wind hour hand forward, until date changes

• Remove working hands

• Put the friction spring on the hour wheel

• Fit dial

• Place all hands towards 12 o’clock

• Set time

• Crown in position II

• Set date

• Crown in position I

Movement holder 

Setting hands

H R150.1A

Movement holder 

Removing setting stem

H R150.1T

225e