Page 8
9.
repeat the above 2-8 steps when the machine runs out of gas and a new
full cylinder is to be replaced.
(
witch shall be undertaken in a flame-free
atmosphere
)
Attention
:
1.
When you operate the machine according to the above procedures and the
heater doesn’t operate correctly after three times ignition, never try to ignite
again under this condition. There is explosion danger caused by high gas
concentration! Contact your dealer in time to clear the reason of
malfunction.
2.
During the use try not to bend the flexible pipe to prevent the break of the
pipe and the danger of gas leakage.
3.
Always equip the correct size of pressure adjusting valve and gas hose
when using the heaters (size of pressure adjusting valve: pressure
Pu=1.5bar±0.15bar. Flow volume Qn=8.0kg/h)
4.
For the length of the flexible tube you may consult your gas supplier. A length with
1.5mis recommended
,
the type of the flexible pipe can be
:
10mm High Pressure
LPG Hose BS3212-Class 2/EN1763-1-Class 3-20Bar propane/butane or of higher
standards.
Figure 4
Figure 5
Figure 3
Figure 2
Figure 1