background image

 

Page 9 

 

Gas supply circuit 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Working principles  

   When the machine is connected to the gas supply, the gas passes in sequence 

the  following  parts:  1.  flame  supervision  device  2.  automatic  shut-off  valve  3. 

needle  valve    4

Nozzle  5

being  ignited  by  the  high-voltage  spark  plug  and 

burning at the burning head. 6

Current occurs in the thermocouple due to the 

heat  output  by  gas  burning.  7

The  thermostat  activates  an  electric  circuit  to 

enable  the  small  electromagnetic  valve  in  the  Flame  supervision  device 
magnetizing the armature of flameout protection valve, the gas passes through 
and burns continuously.   

Item 

Parts name 

Flame supervision device 

Automatic shut-off valve 

Needle valve 

Nozzle 

Thermocouple 

Burning head 

Ignition needle 

Thermostat  

Summary of Contents for K-30

Page 1: ...se read the user manual carefully before using the appliance and operate following the operation instructions in this manual in order to prevent fire or other accidental danger Keep this manual in a safe place for future reference Any understanding problem relates to this manual please contact your dealer HEATER K 30 Réf 93451 User s Manual GB ...

Page 2: ...Page 1 Warning During operation always provide adequate ventilation and keep a 3 5 m safety distance away from combustible articles ...

Page 3: ...view of appliance 5 Dimensions 6 Technical data 6 Operation instructions 7 Gas supply circuit 9 Electric circuit 10 Exploded parts drawing 11 Parts name 12 Requires a hose and regulator 13 Maintenance of the appliance 13 Warning of local regulations 13 Trouble shooting 14 ...

Page 4: ... to avoid danger Warning 1 The appliance shall not be directed towards the gas cylinder 2 Don t use spay products at the location where the heater is used the gas from the spay tin can cause danger of fire and explosion 3 Don t use the appliance in place with combustible powder wastepaper wood crumbs fibre scraps if these powder are sucked in the heater and heated up flake and spark may be ejected...

Page 5: ...ep the appliance far away from inflammable objects 4 When the appliance will not be in use for a long time please remove the plug from the outlet and gas supply pipe from the appliance then put a protection cover on the inlet pipe connection and place the appliance in a dustproof bag then put it in a cool and dry ort out of the reach of child Before you put the appliance in use again make sure the...

Page 6: ...electromagnetic control device which enables power shutoff flame failure and overheating protections The three kinds of protections prevent the LPG gas leakage and potential carbon monoxide poisoning and fire danger induced by LPG gas leakage 3 The LPG gas rate adjustment valve is installed in this product so the heat input can be regulated to fulfill variable requirements at different locations O...

Page 7: ...f destination Degree of electrical protection Gas pressure Rated voltage Motor power input Max gas consumption Max heat input Hot air output G30 I3B P AT BE DK FI FR DE GR IE IT LT NO NL PL PT GB ES SE CH IP44 1 5bar 220 240V 50Hz 65W 2400g h 33kw 1000m 3 h ...

Page 8: ...or nut to make sure no gas leakage happens and open the gas tap Figure 2 4 Set the regulator to the maximum setting 5 Make sure the machine is proper connected with the gas cylinder and the power switch is at the OFF O position plug the power plug in the socket outlet shut on the power switch put the power switch at the ON 1 position Figure 3 6 When the turning of the fan blades becomes stable use...

Page 9: ...ler in time to clear the reason of malfunction 2 During the use try not to bend the flexible pipe to prevent the break of the pipe and the danger of gas leakage 3 Always equip the correct size of pressure adjusting valve and gas hose when using the heaters size of pressure adjusting valve pressure Pu 1 5bar 0 15bar Flow volume Qn 8 0kg h 4 For the length of the flexible tube you may consult your g...

Page 10: ...ing at the burning head 6 Current occurs in the thermocouple due to the heat output by gas burning 7 The thermostat activates an electric circuit to enable the small electromagnetic valve in the Flame supervision device magnetizing the armature of flameout protection valve the gas passes through and burns continuously Item Parts name 1 Flame supervision device 2 Automatic shut off valve 3 Needle v...

Page 11: ...tic valve circuit Ignition circuit Flameout protection circuit B thermostat G integral electromagnetic valve in the flameout protector M fan motor Q power switch Q2 igniter S ignition needle S2 thermocouple Y automatic shut off valve C capacitor ...

Page 12: ...Page 11 Exploded parts drawing ...

Page 13: ... 95 13 Thermocouple 14 Capacitor supporter 15 Capacitor 450V 2μF 16 Gas inlet connector 17 Gas inlet fixed nut 18 Fixation nut M12 P1 0 19 Flame supervision device 20 Automatic shut off valve 21 Copper assembly 22 regulator 23 Mat 24 Ignition 25 Power switch 26 Control box 27 Burning head supporter 28 Coil supporter 29 Cord protection loop 30 nozzle seat 31 Line buckle 32 Power cord and plug 33 no...

Page 14: ... head is stable and the full circle has equal shape Not being like this there is something wrong with the burning 4 When the appliance is used under unsafe circumstances at least a professional person shall be assigned to supervise the operation to keep the appliance away from inflammable objects at any time And after the service wait until the appliance cools down to ambient temperature before le...

Page 15: ...Ignition damaged 4 replace the ignition 5 Automatic shut off valve damaged 5 replace the Automatic shut off valve Flame failure after a few seconds of ignite 1 the distance between the thermocouple and burning head is wrong 1 adjust the distance 2 Press the button of flame supervision device too short 2 press the button of the flame supervision device retain 20 seconds 3 Thermocouple damaged 3 rep...