POWER CORD SIZING
All cords should be sized appropriately to reduce the risk of damage, fire or reduced performance. Reference the table below for recommended
cord sizes.
Note:
These cord sizes are based on a <10% voltage loss, data from the U.S. National Electrical Code Tables 400.5(A) & 400.5(B) and typical
resistances for standard copper wire.
Safety
8
RECOMMENDED ELECTRICAL PRACTICES
CAUTION:
ALWAYS FOLLOW APPLICABLE ELECTRICAL CODES, STANDARDS AND/OR REGULATIONS. CONSULT YOUR LOCAL
ELECTRICAL AUTHORITY OR A LICENSED ELECTRICIAN BEFORE ATTEMPTING TO MODIFY AN ELECTRICAL INSTALLATION. ENSURE
THAT CIRCUIT AND GROUND FAULT PROTECTION DEVICES AND ALL OTHER ELECTRICAL SAFETY EQUIPMENT ARE FUNCTIONING
PROPERLY.
Wire Size
Max Length
16 AWG (1.5 mm
2
)
30 m
14 AWG (2.5 mm
2
)
45 m
12 AWG (4 mm
2
)
75 m
10 AWG (6 mm
2
)
122 m