Three Position
Operatior Station
Three Position
Operatior Station
15
Switch Testing
With the Sequential Switch and the Direction Switch terminal blocks removed all input signals are disabled. Any
input signal to make the door operate will come from this test. For a quick overview there are two types of operator
inputs that can be connected to the SC-325 & SC-650 Controllers for opening and closing the RS-500/600 Doors.
They are Directional Input and Sequential Input. Switches can be connected to one or both connections
simultaneously to the SC-325 & SC-650 Controllers. The table below describes the response of the door when a
specific operation of the door is being carried out and what the door does when a specific operator button has been
pressed.
Manual
Activated
Timed
Activated
Open
Activated
Close
Activated
Stop Activated
Notes
During the
specific
operation
below…..
TIMED
Opening
N/A
N/A
N/A
N/A
Stops Door after
1-2 Seconds
TIMED
Closing
N/A
Reopens
Door &
Starts Delay
N/A
N/A
Stops Door
(Immediately)
During
TIMED
Countdown
Closes
Immediately
Restarts
Time Delay
Exits
Time
Delay
Closes
Door
Should Terminate
Timed Cycle
MANUAL
Opening
N/A
N/A
N/A
N/A
Stops Door
after 1-2 Seconds
When Stop is
pressed & door
stops, pressing
the Manual
button again will
cause the door to
reverse direction
at that point.
MANUAL
Closing
N/A
Opens then
starts Time
Delay
N/A
N/A
Stops Door
(Immediately)
While
Completely
Open (after
MANUAL)
Closes
N/A
N/A
Closes
Door
N/A
While
OPENING
N/A
N/A
N/A
N/A
Stops Door after
1-2 Seconds
While
CLOSING
N/A
Reopens
door &
starts Time
Delay
N/A
N/A
Stops Door
(Immediately)
15.1
Directional Switch Input
The Directional Switch Input is primarily for use with a three position direction
switch similar to the one shown to the right. Operation is simple. Momentarily push
“OPEN” to open the door, momentarily push “CLOSE” to close the door and
momentarily push “STOP” to stop the door. The SC-325 & SC-650 Controllers can
be programmed to perform special events with these directional switches. For
example, if the ‘STOP” button is pressed and held, the door will remain in the
stopped position. None of the other control switches will operate as long as the
“STOP” connection to the controller is completed. Similarly, if the “OPEN” button
is pressed and held, the door will remain in the open position. And, if the “CLOSE”
button is pressed and held, the door will remain in the closed position.
Summary of Contents for RS-500 Series
Page 20: ...Page 20 RS500 600 Series Doors Part No 4801 5158 Rev 1 2017 AC DC Harness ...
Page 31: ...Part No 4801 5158 Rev 1 2017 RS500 600 Series Doors Page 31 Brake Rectifier Jumper ...
Page 41: ...Part No 4801 5158 Rev 1 2017 RS500 600 Series Doors Page 41 23 4 Matrix2 Loop Sensor ...
Page 43: ...Part No 4801 5158 Rev 1 2017 RS500 600 Series Doors Page 43 ...
Page 44: ...Page 44 RS500 600 Series Doors Part No 4801 5158 Rev 1 2017 ...