Part No 4801-5314 Rev 06-2015
Float & Pump Replacement
PolarCool
RollSeal, Inc. • 1733 County Road 68 • Bremen, Alabama 35033 • 256-287-7000
PolarCool
Pump Replacement
Units Manufactured After May 26, 2015
NOTE: If water is not disconnected, turn off the water hose.
NOTE: Do not allow the pump to run without water in the reservoir. Without
water, the pump may be damaged.
Removing Pump
1.
Before removing pump, ensure electrical power has
been disconnected and water supply is turned off
and/or removed.
2.
Remove the Pads. See manual
4801-5035 PolarCool User’s Manual for more
information.
3.
Remove the Control Panel and lay it as shown in
Illustration 1. The Control Panel is attached to the
unit with four (4) allen screws. See manual 4801-
5035 PolarCool User’s Manual for more information.
Use a protective cover between the touch pad and
unit side.
4.
Disconnect the Black, Green and White wires of the
Pump cable on the Control Panel as shown in
Diagram 1.
5.
From the interior of the unit, loosen the cable gland on the
junction box and remove the old Pump cable. See Illustration
2.
Warning!
Disconnect All Power Sources Before Installing This Equipment! Failure To
Disconnect Power Source Can Result In Property Damage, Serious Injury Or Death!
Illustration 1
Pump
Cable
Green
Wire
White
Wire
Black Wire
Illustration 2
Cable
Gland for
Pump
Cable
!