6
The heat release rate of the appliance is
RFG 12
7 kW with G30/G31
6.5 kW with G20/G25
The gas consumption is of :
687 l/h with G20 and 799 l/h with G25
552 g/h withG30 and 543 g/h with G31
For a use in natural gas, change the injectors of the burner and the pilot light one.
They are delivered in a small plastic bag placed in the package.
To change the burner injector, unscrew the bottom part of the fryer and with a key 7,
remove the injector. The pilot light one is accessible with a flat screwdriver
Connect the appliance to the gas supply pipe, interposing a stop valve which enables
the appliance to be insulated from the rest of the installation.
Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.
The fresh air flow required for combustion air supply is:
-
RFG 12 13m3/h
General conditions of installation
The installation and maintenance of the appliance must be carried out in compliance
with the statutory texts and good practices in force, mainly:
General specifications
For all appliances:
Article GZ
Installation with combustible gases and liquefied hydrocarbons.
Then, according to use:
Article CH
Heating, ventilation, refrigeration
Air conditioning and domestic hot water steam generation.
Article GC
Installation of appliances to be used for catering
Specific provisions for each type of establishment to which the public is admitted
(hospitals, shops, etcB)
Important: Never change the diameter of the injectors.