The heat release rate of the appliance is  

 

RFG 12

 

7 kW with G30/G31

 

 

 

 

 

 

 

 

 

 

6.5 kW with G20/G25 

 

 

The gas consumption is of :

 

 

687 l/h with G20 and 799 l/h with G25

 

 

 

 

 

 

 

552 g/h withG30 and 543 g/h with G31

 

 

For  a  use  in  natural  gas,  change  the  injectors  of  the  burner  and  the  pilot  light  one. 
They are delivered in a small plastic bag placed in the package.

 

To change the burner injector, unscrew the bottom part of the fryer and with a  key 7, 
remove the injector. The pilot light one is accessible with a flat screwdriver

 

 

Connect the appliance to the gas supply pipe, interposing a stop valve which enables 
the appliance to be insulated from the rest of the installation. 

 

 

Check the supply pressure using a manometer when all the burners are lit. It must be 
equal to the indications on the rating plate.

 

 

The fresh air flow required for combustion air supply is:

 

 

-

 RFG 12   13m3/h

 

 

General conditions of installation

 

 

The installation and maintenance of the appliance must be carried out in compliance 
with the statutory texts and good practices in force, mainly:

 

  

General specifications

 

 

For all appliances:

 

Article GZ

 

Installation with combustible gases and liquefied hydrocarbons.

 

  

Then, according to use:

 

 

Article CH

 

Heating, ventilation, refrigeration

 

Air conditioning and domestic hot water steam generation.

 

 

Article GC

 

Installation of appliances to be used for catering

 

Specific  provisions  for  each  type  of  establishment  to  which  the  public  is  admitted 
(hospitals, shops, etcB)

 

 

Important: Never change the diameter of the injectors.

 

 

Summary of Contents for RFG 12

Page 1: ...INSTRUCTION MANUAL FOR USE AND INSTALLATION GAS FRYER RFG 12 Made in France Made in France Made in France Made in France December 2014 ...

Page 2: ...uctions 3 2 Contents of cardboard packaging 4 3 Conformity of use 4 4 Way of functioning 5 5 Functioning Manipulation 5 6 7 6 Cleaning and maintenance 8 7 Technical specifications 9 Appendix part list and exploded view 10 11 2 ...

Page 3: ...o not use the appliance for other functions than determined use Do not leave the pipe or hose purchased separately from a specialised shop in the contact of hot surfaces The appliance should not be used close to combustible materials During use look after not to obstruct hearings of aeration of the appliance Never exceed the maximum capacity of your fryer which is of 2 5kg Never place the lid on t...

Page 4: ... basket A basket hoder A set of natural gas injectors The present note See the exploded of the RFG 12 at the end of the document 3 CONFORMITY OF USE Use the machine only to cook some food 4 Piezo power on knob Thermostatic tap power regulation Draining tap 1 2 3 1 2 3 ...

Page 5: ...G a Installation Assembly Unpack carefully the device of its packaging Remove the protective film around the machine Screw up the feet and the handle on the lid Place the fryer on a plane and heatproof surface Never place the device near a wall or near a partition makes of combustible materials even if it is very well isolated A distance of minimum 10 cm with the partition or the wall is necessary...

Page 6: ...ation Check the supply pressure using a manometer when all the burners are lit It must be equal to the indications on the rating plate The fresh air flow required for combustion air supply is RFG 12 13m3 h General conditions of installation The installation and maintenance of the appliance must be carried out in compliance with the statutory texts and good practices in force mainly General specifi...

Page 7: ...liance simultaneously with the set knob Set knob n 3 on picture Switches on the appliance knob pressed simultaneously with piezo Controls power 7 Country of destination Category Gas Pressures Diameter of in jector FR BE II2E 3 G20 G25 G30 G31 20 25 28 30 37 140 90 LU DE II2E3B P G20 G30 G31 20 50 140 80 LU II2E3 G20 G30 G31 20 28 30 37 140 80 AT CH CY DK EE FI HR LT LV NO RO SE SI SK TR II2H3B P G...

Page 8: ...he appliance is completely switched off Close the butane or propane cartridge Clean the appliance See 6 Cleaning d Breakdown repair In case of breakdown or of damaged part please call your after sales service and confide any technical operation to qualified person When you contact the after sales service of your distributor or your store give him the complete reference of your device commercial na...

Page 9: ... respect cur rent regulations or instructions appearing in this user guide Cannot benefit from the guarantee the repairs required as a result of false opera tions of inappropriate use of carelessness or of excess loads of the device as well as those resulting from defective installations The damage due to shocks bad weather is not flatware by the guarantee The ma terial travels at the risks of the...

Page 10: ...10 Nomenclature Friteuse RFG 12 Spare parts FryerRFG 12 ...

Page 11: ...11 ...

Page 12: ...12 ...

Reviews: