13
6. CLEANING AND MAINTENANCE
Disconnect the device
- Clean regularly the metallic parts after each use by using only use non-abrasive
products, warm water and wash liquid: avoid the abrasive toweling. Rinse your
device with a wet sponge and dry it with a soft cloth.
- Dry the device with a clean soft cloth.
- Never clean the device under a water jet, the infiltrations would risk to damage it in
an irreparable way.
- Never immerse the cord or the plug in the water or quite other liquid to avoid any
electric shock
- Every week the condenser must be removed from any dust with a vacuum-cleaner.
First, always disconnect the display before doing this operation. Then, to have an
access to the condenser, remove the front grid of the display. The container for the
evaporation of condensation particles must be cleaned with a wet sponge as well.
To have an access, remove the side grid of the display.
CAUTION :
In places with a high rate of humidity (>60%), it is obligatory to
proceed to a total defrost every week.
7. TECHNICAL SPECIFICATIONS
Model
RDN 600 F
RDN 800 F
Effective Volume
360 l
340 l
Dimensions
650x600x1865
650x800x1865
Weight
180 Kg
200 Kg
Power
900 W
940 W
Gas
R 404 A
R 404 A
Temperature
-18° à -5° C
-18° à -5° C
Voltage
220-240 V ~
220-240 V ~
Frequency
50-60 Hz
50-60 Hz
Grids
465 x 455 (x5)
465 x 455 (x5)
Climatic Level
Tropicalised condensing
unit
Tropicalised condensing
unit
Maximum weight/grid
10 kg
10 kg
Wires colours correspondence:
Phase
Brown or Black or Grey
Neutral
Blue
Earth
Yellow-Green