4.3 View and change sensor mode
4.4 Light levels of light intensity values
4.5 Light intensity detection
4.6 Low battery notification
4.7 UP button
Press the
SUN
and
P2
buttons for once second
Hold the sensor toward the light
Response
The unit will indicate light level
When the battery needs changing, the currently selected light level LED will blink every 2 minutes
To Change light level setting:
Press the SUN key repeatedly until the desired light level flashes.
To view the current mode, press the
SUN
button for one second
1 blink indicates mode 1
2 blinks indicate mode 2
3 blinks indicate mode 3
To change the mode:
Hold the
SUN
button until the LED blinks 5 times. The mode has now shifted up by one. E.g. Mode 2 has
changed to Mode 3.
The up button can be used to manually overide the sensor and tell the shade to go up.
0 Level
Not Operational
1 Level
15kLUX
2 Level
30kLUX
3 Level
45kLUX
4 Level
60kLUX