rollease acmeda Automate Internal Sun Sensor Manual Download Page 4

| Automate Programming Instructions | Interior Sun Sensor 

ROLLEASE ACMEDA

SAFETY

WARNING: Important safety instructions to be read before installation and use.

Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty.

It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference.

• 

Do not expose to water, moisture, humid and damp environments or extreme temperatures.

• 

Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge

• 

should not be allowed to use this product.

• 

Use or modification outside the scope of this instruction manual will void warranty.

• 

Installation and programming to be performed by a suitably qualified installer.

• 

Follow installation instructions.

• 

For use with motorized shading devices.

• 

Keep away from children.

• 

Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.

• 

Keep clear when in operation.

• 

Replace battery with correctly specified type.

Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of 

R&TT EC Directive 1999/5/EC

Statement Regarding FCC Compliance

 

This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that may cause undesired operation.

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which Can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

•Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to 

operate the equipment.

Do not dispose of in general waste. 
Please recycle batteries and damaged electrical products appropriately.

Summary of Contents for Automate Internal Sun Sensor

Page 1: ...n Sensor FEATURES 3 Modes of operation Close Mode Open Close Mode Shade Detect Mode 4 Light sensitivity levels Low battery warning Internal sun sensor for automatic shade control INSTR MTRF SUNSENS V1...

Page 2: ...5 4 FUNCTIONAL OVERVIEW 6 4 1 Buttons 6 4 2 Modes 6 4 3 View and change sensor mode 7 4 4 Light levels of light intensity values 7 4 5 Light intensity detection 7 4 6 Low battery notification 7 4 7 UP...

Page 3: ...L SPECIFICATIONS Voltage 3V CR2032 Standby Current 5uA Frequency 433 92 MHz Transmitting Power 10 milliwatt Ambient Operating Temperature 10 C 50 C Light Intensity Level Range 15 75 Klux Transmission...

Page 4: ...ject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation...

Page 5: ...screw driver where notches meet on the sensor Remove old battery by pressing up from under the batterys position Push new battery in with the facing outwards Replace cover by aligning notches and pres...

Page 6: ...de Pre set light level reached Pre set light level reached Pre set light level reached Light level stays above pre set for 2 mins Light level stays above pre set for 2 mins Light level stays above pre...

Page 7: ...elected light level LED will blink every 2 minutes To Change light level setting Press the SUN key repeatedly until the desired light level flashes To view the current mode press the SUN button for on...

Page 8: ...to operate Acmeda line EL motors The default mode is ARC protocol To toggle between ARC EL modes follow the following steps HOLD P2 whilst inserting battery To check which mode the sensor is currently...

Page 9: ...tor P1 Button 6 2 Using a pre existing Controller Hold P1 button on motor head Hold P2 on sensor to add or remove Motor Response Motor Response Press P2 on existing controller Press P2 on existing con...

Page 10: ...y Check battery polarity Ref Section 3 2 Radio interference Shielding Ensure remote is positioned away from metal objects and that aerial on motor or reciever is kept straight and away from metal Sens...

Page 11: ...ROLLEASE ACMEDA Automate Programming Instructions Interior Sun Sensor 11 8 NOTES...

Page 12: ...nch Unit 1 41 Mulgul Road Malaga WA 6090 T 61 8 9248 5571 F 61 8 9248 5572 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford CT 06902 6320 T 1 203 964 1573 F 1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Co...

Reviews: