background image

AUTOMATE

 

  

 

Interior Sun Sensor

FEATURES:

• 

3 Modes of operation:

 

 

- Close Mode

 

 

- Open / Close Mode

 

 

- Shade Detect Mode

• 

4 Light sensitivity levels

• 

Low battery warning

Internal sun sensor for automatic shade control.

INS

TR. MTRF-SUNSENS V1.1 JUL

Y 2016

433 MHz

Summary of Contents for Automate Internal Sun Sensor

Page 1: ...n Sensor FEATURES 3 Modes of operation Close Mode Open Close Mode Shade Detect Mode 4 Light sensitivity levels Low battery warning Internal sun sensor for automatic shade control INSTR MTRF SUNSENS V1...

Page 2: ...5 4 FUNCTIONAL OVERVIEW 6 4 1 Buttons 6 4 2 Modes 6 4 3 View and change sensor mode 7 4 4 Light levels of light intensity values 7 4 5 Light intensity detection 7 4 6 Low battery notification 7 4 7 UP...

Page 3: ...L SPECIFICATIONS Voltage 3V CR2032 Standby Current 5uA Frequency 433 92 MHz Transmitting Power 10 milliwatt Ambient Operating Temperature 10 C 50 C Light Intensity Level Range 15 75 Klux Transmission...

Page 4: ...ject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation...

Page 5: ...screw driver where notches meet on the sensor Remove old battery by pressing up from under the batterys position Push new battery in with the facing outwards Replace cover by aligning notches and pres...

Page 6: ...de Pre set light level reached Pre set light level reached Pre set light level reached Light level stays above pre set for 2 mins Light level stays above pre set for 2 mins Light level stays above pre...

Page 7: ...elected light level LED will blink every 2 minutes To Change light level setting Press the SUN key repeatedly until the desired light level flashes To view the current mode press the SUN button for on...

Page 8: ...to operate Acmeda line EL motors The default mode is ARC protocol To toggle between ARC EL modes follow the following steps HOLD P2 whilst inserting battery To check which mode the sensor is currently...

Page 9: ...tor P1 Button 6 2 Using a pre existing Controller Hold P1 button on motor head Hold P2 on sensor to add or remove Motor Response Motor Response Press P2 on existing controller Press P2 on existing con...

Page 10: ...y Check battery polarity Ref Section 3 2 Radio interference Shielding Ensure remote is positioned away from metal objects and that aerial on motor or reciever is kept straight and away from metal Sens...

Page 11: ...ROLLEASE ACMEDA Automate Programming Instructions Interior Sun Sensor 11 8 NOTES...

Page 12: ...nch Unit 1 41 Mulgul Road Malaga WA 6090 T 61 8 9248 5571 F 61 8 9248 5572 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford CT 06902 6320 T 1 203 964 1573 F 1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Co...

Reviews: