background image

Ink Switching Method

 To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through 

this manual completely and store it in a safe location.

 Unauthorized copying or transferral, in whole or in part, of this manual is prohibited.

 The contents of this operation manual and the specifications of this product are subject to change without notice.

 The operation manual and the product have been prepared and tested as much as possible. If you find any misprints or 

errors, please inform us.

 Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage that may occur through use of this 

product, regardless of any failure to perform on the part of this product.

 Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage that may occur with respect to any 

article made using this product.

About this Manual

This manual explains how to switch the ink being used from 

ECO-SOL MAX 2

 ink (hereinafter called 

MAX 2 ink

) to 

ECO-SOL 

MAX 3

 ink (hereinafter called 

MAX 3 ink

).*

To prevent the MAX 2 ink and the MAX 3 ink from mixing, perform operations according to the procedures given in this manual.

* Colors with MAX 3 ink are different than with MAX 2 ink.

ECO-SOL MAX2

ECO-SOL MAX3

Summary of Contents for VersaCAMM ECO-SOL MAX3

Page 1: ...please inform us Roland DG Corp assumes no responsibility for any direct or indirect loss or damage that may occur through use of this product regardless of any failure to perform on the part of this...

Page 2: ...Changes and Precautions after Switching the Ink 17 Change When to Perform Manual Cleaning 17 Change Cleaning Locations During Manual Cleaning 18 Daily Precautions 18 When Not in Use for a Prolonged Pe...

Page 3: ...time Approx 5 minutes STEP 2 Switching the Ink P 5 Required time Approx 20 to 30 minutes STEP 3 Cleaning of the Periphery of the Print Heads Manual Cleaning P 6 Required time Approx 10 minutes STEP 4...

Page 4: ...3 are necessary for the operations in this manual Check that the following files are present Firmware XF640Firm240 exe in the Firmware folder Updater LocalUpdater exe Ver 5 5 0 or later in the Roland...

Page 5: ...drain bottle be sure to wait for the screen to display EMPTY DRAIN BOTTLE After discarding the discharged fluid promptly attach the drain bottle to the machine Failing to follow this procedure may ca...

Page 6: ...the instructions and never touch any area not specified in the instructions Failure to observe these instructions may cause the machine to move suddenly resulting in injury 4 18 51 46 26 4 0 166 5 6 5...

Page 7: ...from the message OPEN COVER L shown above is displayed a warning beep will sound to warn you of the print heads drying out When the warning beep sounds attach the left and right covers close the fron...

Page 8: ...igure to discharge any static electricity Put on the pair of gloves included Moisten the cleaning stick with the cleaning liquid 12 0 18 4 4 Click 07 0 0 0 5 Usethecleaningliquidthatyouhavebeenusingsi...

Page 9: ...Only moisten the part indicated with diagonal lines in location with cleaning liquid on the cleaning stick Press Close the left cover Close the right cover When the screen shown in the figure appears...

Page 10: ...erations with the procedures in this manual Refer to the user s manual of the model that you are using and perform the operations according to the details listed under P 20 When Operations Are Interru...

Page 11: ...he front cover Replace the first felt wiper Close the front cover Press 12 0 18 4 4 4 2 9 2 4 0 5 15 18 4 4 12 0 18 4 4 4 2 6 0 5 Pull up and out Disconnect the hooks Usingthetweezerstopressonthehooki...

Page 12: ...on under step 2 3 Exit the CHANGE INK SET menu Close the front cover Press Close the right cover Open the left cover Attach the cut rail Press Close the left cover The screen shown in the figure appea...

Page 13: ...rsaWorks Windows 8 1 Click on the Start screen Click Initialize Application for VersaWorks From this point the procedure differs depending on the type of printer that is connected to VersaWorks When o...

Page 14: ...nter that has been switched to MAX 3 ink to VersaWorks Start VersaWorks The Printer Settings screen will appear Set IP Address to the IP address of the printer that has been switched to MAX 3 ink Clic...

Page 15: ...switch to MAX 3 ink When a printer that does not use MAX 3 ink is connected to VersaWorks 2 Temporarily delete the printer that has been switched to MAX 3 ink from VersaWorks Start VersaWorks When th...

Page 16: ...ink Click Verify Check that Ink Type is the MAX 3 ink Thisindicatesthatyouhavesuccessfullyreconnect edtoaprinterthathasbeenswitchedtoMAX3ink Click Apply The printer that has been switched to MAX 3 in...

Page 17: ...also an effective means of improving the symptoms After switching to MAX 3 ink Cleaning timing Cleaning method Remarks Before the start of daily operations Normal cleaning Carry out a printing test If...

Page 18: ...to close the left and right covers after performing maintenance This machine periodically performs automatic maintenance but this will not be performed if the front cover is open If the machine is le...

Page 19: ...the discharged fluid CAUTION Before you detach the drain bottle be sure to wait for the screen to display EMPTY DRAIN BOTTLE Failing to do so may cause discharged fluid to flow out of the machine and...

Page 20: ...The subsequent work to perform varies depending on the point when the operations were interrupted Refer to the follow ing sections and then perform operations according to the corresponding page of t...

Page 21: ...R2 160408 FA01047...

Reviews: