Chapter 3 Appendix
30
3-1 What to Do If
The Drying-heater Unit Doesn't Get Hot.
Is the power cord connected?
Connect the power cord for the drying-heater unit securely.
☞
P. 24, "Connecting the Cables"
Is the drying-heater unit cable connected?
Connect the drying-heater unit cable to the printer unit.
☞
P. 24, "Connecting the Cables"
Is [OPTION DRYER] on the printer set to "EN-
ABLE" as its value?
The drying-heater unit doesn't operate unless this is set to
"ENABLE." Check the setting.
☞
P. 26, "What to Do First"
Is the power switch on?
Make sure the power switch is on.
☞
P. 26, "Switching the Power On and Off"
Is the temperature of the room too low?
Use the machine in an environment where the temperature
is 20 to 32˚C (68 to 90˚F).
The Blower-fan Unit Doesn't Run.
Is the blower-fan unit cable connected?
Connect the blower-fan unit cable to the printer unit.
☞
P. 24, "Connecting the Cables"
Is [BLOWER FAN] on the printer set to "ENABLE"
as its value?
The blower-fan unit doesn't operate unless this is set to "EN-
ABLE." Check the setting.
☞
P. 28, "Switching the Blower-fan Unit On"
If a Message Appears
[OPTION-DRYER IS NOT CONNECTED]
The unit is not connected correctly. Switch off the power to
all devices, then check the connection to the unit.
☞
P. 24, "Connecting the Cables"
☞
P. 26, "What to Do First"
Summary of Contents for SOLJET PROIII DU-540
Page 16: ...14...
Page 17: ...15 Chapter 1 Introduction...
Page 27: ...25 Chapter 2 Operation...
Page 31: ...29 Chapter 3 Appendix...
Page 35: ......
Page 36: ...R1 070808...