Part 2
22
3. Operating Each Function
Replotting (Recutting)
Pressing the
[REPLOT]
key calls up the cutting data stored in the PNC-3100's data buffer and executes the replotting
procedure. The data buffer is the place where data received from the computer is stored temporarily. (The data in the
data buffer can be erased by switching off the power or holding down the
[BUFFER CLEAR]
key for at least 0.5 sec.)
When replotting is executed, the entire data content of the data buffer is called up. When you perform replotting, clear
the data from the data buffer before sending the cutting for replotting from the computer.
1
2
3
Press the
[REPLOT]
key.
• Replot (recutting) will start.
Download Data
Download the cutting data using the oper-
ating software of computer.
• When cutting is finished, replace the
workpiece.
• If necessary set the home position (refer
to page 14) and Z0 (refer to page 15).
Device Name
PNC-3100
Interface
RS-232C
Protocol
Baud rate
: 9600
Data bit
: 8
Stop bit
: 1
Parity
: None
Handshake
: Xon/Xoff
OK
CANCEL
Confirm the settings, then click "
OK
".
Press the
[BUFFER CLEAR]
key for at
least 0.5 seconds.
• The data buffer is cleared.
• When data in the buffer is erased, the
coordinate display for the Y axis begins
to flashes.
X
-AXIS
000
Y
-AXIS
000
Z
-AXIS
000
The Y-axis coordinate
display flashes.
At least
0.5 seconds.
Summary of Contents for PNC-3100 CAMM-3
Page 54: ...Appendix 44 MEMO ...