background image

How

 

to

 

use

manual

 

correction

in

 

VPanel

DWX

50

Ver.1.0

  

Jan

 

28th,

 

2013

 

Summary of Contents for DWX-50

Page 1: ...How to use manual correction in VPanel DWX 50 Ver 1 0 Jan 28th 2013...

Page 2: ...Contents 1 Manual correction 1 1 Introduction 1 2 How to find a displacement in Z axis 2 Manual correction using a test block Appendix Calculation sheet...

Page 3: ...axis is as follows with DWX 50 XYZ origin will be set at the center of the clamp A and B origins are the point where the clamp is leveled Manual correction A correction window comes up when you click...

Page 4: ...s used when an object is bigger smaller in certain direction Available offset range 99 500 to 100 500 in increments of 0 001 Default 100 2 A axis back side inversion correction of A axis In two surafe...

Page 5: ...e thickness in Z direction is thicker thinner than you expected The function varies depending on the direction Available offset range 1 00 mm to 1 00 mm in increments of 0 01 mm Default 0 mm If you in...

Page 6: ...may not occur Correction of Y origin In Y axis direction cutting location is inverted in two surface cutting therefore the displacement could occur Correction of Y origin can minimize the displacement...

Page 7: ...oint you expected No difference between the one you expected and actual result CORRECT 2 Z origin is higher than you expected The cutting result will be thicker INCORRECT If you input a positive offse...

Page 8: ...xpected The cutting result will be thinner INCORRECT If you input a positive offset value the thickness will be thicker If you input 0 01 mm the thickness will be 0 02 mm thicker Z origin Z Y 0 02mm i...

Page 9: ...an appropriate way Case 1 Correction of distance in the Z direction is required The amount of error increases in proportion to the thickness Case 2 Inversion correction of the A axis is required The e...

Page 10: ...1 Outputting the test data Workflow 1 Set a wax disc on the clamp 2 Set a R1 ball end mill on the stocker 1 3 Set the air pressure as 0 05MPa 4 Output the test data DWX 50_correctiontest prn from VPan...

Page 11: ...rt using a caliper NOTE Measure the shadow area upper part for X1 X2 Y1 Do not measure at curved part for Z1 and Y2 Measure the upper part above the center for Y3 Measure the lower part below the cent...

Page 12: ...2 Enter each measurement value in the calculation sheet 2 3 Entering the current correction value Check each correction value in VPanel Enter the current correction value in the calculation sheet...

Page 13: ...will be shown in the calculation sheet Enter each correction value in VPanel Output the test data again in reference to the step 2 1 Measure the test block in reference to the step 2 2 Manual correcti...

Reviews: