WARNING: RISK OF ELECTRICAL SHOCK 

WHAT CAN HAPPEN 

HOW TO AVOID IT 

 

Electrical Grounding:

 Failure to provide adequate 

grounding to the compressor could result in serious 

injury or death from electrocution. 

 

Always make certain that the electrical circuit to which 

the compressor is connected provides proper 

electrical grounding, correct voltage, and adequate 

fuse protection. If you are unsure, or have any 

questions about proper electrical grounding, correct 

voltage, or adequate fuse protection please call us toll-

free at 800-310-3573. 

 

Your air compressor is powered by electricity. Like any 

electrically powered device, if it is not used properly it 

may cause electric shock. 

 

Never operate the compressor outdoors when it is 

raining, snowing, or in wet conditions. 

 

Never let your electrical cord lay in water. 

 

Never operate the compressor with a damaged power 

cord, or with protective covers damaged or removed. 

 

Never touch plug with wet hands. 

 

Never pull on electric cord to disconnect from the 

outlet. 

 

Serious injury or death can occur if repairs are 

attempted by unauthorized personnel. 

 

Any electrical repairs or wiring performed on this 

compressor should only be performed by ROLAIR 

authorized service personnel and in accordance with 

all national and local electrical codes. 

 

 

WARNING: RISK FROM FLYING OBJECTS 

WHAT CAN HAPPEN 

HOW TO AVOID IT 

 

Serious injury and property damage can occur from 

loose debris being propelled at high speeds from the 

compressed air stream. 

 

Always wear certified safety equipment: ANSI Z87.1 

eye protection (CAN/CSA Z94.3) with side shields 

when using the compressor. 

 

Never direct the air stream, nozzle, or sprayer towards 

any part of your body, other people, or animals. 

 

Always turn off the compressor and drain tank 

pressure completely before attempting maintenance 

or attaching air hose or tools. 

 

 

WARNING: RISK OF HOT SURFACES 

WHAT CAN HAPPEN 

HOW TO AVOID IT 

 

Serious burn injuries can result from touching exposed 

metal parts such as the engine or motor, pump, or any 

part of the copper/braided discharge lines and 

components. These parts will become hot during 

operation and stay hot for an extended period of time 

even after the compressor is shut down. 

 

Never touch any of the exposed metal parts during 

operation and for an extended period of time after 

shut down. 

 

Do not reach around shrouds or attempt any 

maintenance until the unit has been allowed to 

completely cool. 

 

 

 

 

Summary of Contents for V5160PT03XB

Page 1: ...whatsoever on the proper installation operation or maintenance of your air compressor please feel free to contact our Customer Service Department at 1 800 310 3573 We would love to hear from you MODEL...

Page 2: ...on receipt of your air compressor and prior to completely uncrating the following steps should be taken Step 1 Remove box and inspect compressor for damage that may have occurred during shipment If an...

Page 3: ...ined in this manual you can achieve years of trouble free service from your new air compressor If you have any additional safety or operating questions after reading this manual please contact your di...

Page 4: ...repeatedly and could result in overheating fire and personal injury or property damage Always remain in attendance with the compressor when it is operating Always turn off and unplug the compressor w...

Page 5: ...r tank pressure can lead to a violent air tank explosion The air compressor is designed to safely operate and withstand specific factory set pressure Never make adjustments or parts substitutions to c...

Page 6: ...repairs or wiring performed on this compressor should only be performed by ROLAIR authorized service personnel and in accordance with all national and local electrical codes WARNING RISK FROM FLYING...

Page 7: ...tective guards shrouds or covers will expose you to moving parts and can result in serious injury or death Any repairs to the air compressor must only be made by ROLAIR factory authorized personnel WA...

Page 8: ...area of operation FOR HONDA ENGINES EQUIPPED WITH OPTIONAL ELECTRIC START Review the instructions provided in the Honda owner s manual included with your air compressor If you re unable to locate that...

Page 9: ...e overall performance and life of the unit PIPING FIT UP Always position air compressor to avoid an excessive amount of tension between the external air lines and connection at the air tank The piping...

Page 10: ...a starter with properly sized thermal overload s The starter should protect the motor from overheating and burn out due to an overload low voltage or single phasing of a 3 phase circuit Failure to ins...

Page 11: ...components making the compressor dangerous to operate Always operate and or store compressor in a clean dry location with good ventilation FREEZING TEMPERATURES Proper fluid maintenance and warm up p...

Page 12: ...ng fusing and disconnect switches Efficiency and safety are the primary concerns when selecting components for compressed air systems Products of inferior quality can not only hinder the performance o...

Page 13: ...ompressor Oil X Clean Change Air Filter X Perform Pump Up Time Test X Check Operation of System Controls X Check Air Tanks for Dents Leaks X Tank Inspection by Certified Inspector X Check and re torqu...

Page 14: ...ut of alignment Reposition pulley or flywheel Flywheel pulley wobble Replace appropriate item Improper belt tension Adjust belt tension Oil in discharge air or oil blowing out of crankcase vent Wrong...

Page 15: ...ies of merchantability and fitness for purpose and of any other obligations and or liabilities on the part of Associate Engineering Corporation Associate Engineering Corporation neither assumes nor au...

Page 16: ...para realizar la prueba de tiempo de bombeo y registrar los resultados al arrancar la compresora de aire por primera vez Lugar y fecha de compra Voltios Modelo Hz N de serie C F De 0 a _____ psi De 0...

Page 17: ...instrucciones de este manual podr alcanzar a os de vida til sin problemas de su nueva compresora de aire Si despu s de leer este manual tiene alguna pregunta adicional sobre la seguridad o el funciona...

Page 18: ...erada y repetidamente y eso puede resultar en sobrecalentamiento incendio y heridas personales o da os a la propiedad Siempre permanezca atendiendo al compresor cuando el mismo est funcionando Siempre...

Page 19: ...la f brica Nunca realice ajustes o substituya piezas componentes que controlen la presi n del tanque de aire o las presiones operativas fijadas en la f brica No altere la configuraci n de f brica de...

Page 20: ...d certificado gafas protectoras para los ojos ANSI Z87 1 CAN CSA Z94 3 con protectores laterales cuando usa el compresor Nunca dirija la corriente de aire la boquilla o el rociador hacia ninguna parte...

Page 21: ...erse durante el curso de una operaci n normal resultando en una ca da desde una mesa un banco de trabajo un techo u otra plataforma causando da os al compresor a la propiedad y resultando en heridas s...

Page 22: ...ene completamente la presi n del tanque del compresor de aire y deje abierta la v lvula de drenaje antes y despu s de arrancar el motor Deje funcionar el compresor de aire con el drenaje del tanque ab...

Page 23: ...entaci n Las compresoras de aire utilizan motores inductivos que requieren consumir un amperaje de carga completa de 3 a 5 veces m s para arrancar correctamente La mayor a de los generadores no produc...

Page 24: ...llenar el c rter con aceite aseg rese de usar un aceite monogrado no detergente NO USE UN ACEITE DETERGENTE Revise el aceite antes de arrancar Antes de ser enviadas las unidades completas se llenan c...

Page 25: ...dad completa de amperaje de factor de servicio de placa de identificaci n y es posible que deban acondicionarse para evitar el sobrecalentamiento reiterado Es posible que las compresoras de acci n dir...

Page 26: ...lujo de aire y la temperatura No se f e de una v lvula de retenci n para aislar una compresora de un tanque presurizado o de un sistema de servicio de aire comprimido durante los procedimientos de man...

Page 27: ...re X Revisar la condici n de las almohadillas antivibraci n X Ajustar reajustar los pernos X Revisar la tensi n de la correa X Revisar el funcionamiento de la v lvula de seguridad X Cambiar el aceite...

Page 28: ...Use calor para aflojar el sello de Loctite en las v lvulas de drenado las poleas del motor y los volantes antes de tratar de quitarlo TABLA DE PARES DE TORSI N PULGADAS LIBRAS Determine el tipo de bo...

Page 29: ...a o volante de motor desalineados Ajuste la posici n de la polea o el volante Bamboleo del volante o la polea Reemplace el elemento correspondiente Tensi n inapropiada de la correa Ajuste la tensi n d...

Page 30: ...e otras las garant as de comerciabilidad y de idoneidad para un fin espec fico y todas las dem s obligaciones y o responsabilidades por parte de Associate Engineering Corporation Associate Engineering...

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Reviews: