AIR COMPRESSOR OPERATION
LUBRICATION
Prior to daily operation, make a habit of checking the oil level in your compressor pump. A
sight gauge on the outside of the pump’s crankcase is provided to make the job easier.
Always maintain the oil level to read 2/3 full on the sight gauge. Oil levels over this amount
will result in oil blowing past the rings or through the crankcase breather. Lower amounts of
oil will result in insufficient lubrication of moving parts.
Reciprocating compressors will consume a certain amount of oil under normal operation. If
you are concerned about your oil consumption, monitor and record oil consumption daily and
consult your local dealer. When filling your crankcase with oil, be sure to use a single
viscosity, non-detergent oil. DO NOT USE A DETERGENT OIL!!
OIL SIGHT GAUGE
Oil Type Table
Temperature
0° - 32°
33° - 55°
56° & Above
Non-detergent
Straight Weight
10 WT
20 WT
30 WT
IMPORTANT
Unit must be level when in operation.