Leveling – Bio dispenser

Enter the 

[New Creator K APP] > [Bed Leveling] > [RIGHT POSITION]

Click the

 [HOME]

 button to adjust the distance from a nozzle and a bed. 

After clicking the 

[SET HOME POSITION]

, choose the distance to move among 

[0.1MM], [1MM]

 and 

[10MM]

After selecting the moving distance you want, click up and down arrows to adjust the distance between an output bed and a nozzle, up 
to the properties such as viscosities of materials.
The thickness gauge provided will be helpful for this.
Click the

 [FINISH] 

button.

1
2
3
4

5
6

HOW TO USE

HOW TO USE

Leveling – Bio extruder

Enter the 

[New Creator K APP] > [Bed Leveling] > [LEFT POSITION]

Click the

 [HOME]

 button to adjust the distance from a nozzle and a bed.

After clicking the 

[SET HOME POSITION]

, choose the distance to move among 

[0.1MM], [1MM] and [10MM]

After selecting the moving distance you want, click up and down arrows to adjust the distance between an output bed and a nozzle, up 
to the properties such as viscosities of materials.
The thickness gauge provided will be helpful for this.
Click the 

[FINISH]

 button to finish leveling.

TIP :

 Before leveling, adjust the left extruder to make the extruder is parallel to the dispenser, or adapt the height of the extruder higher 

        than the dispenser. If the layer is 0.2mm, using 0.1mm thickness gauge is recommended for leveling. In the following printing, 
        the height you have set will be the offset value of the nozzle. 

1
2
3
4

5
6

TIP :

 In the following printing, the height you have set will be the offset value of the nozzle. 

Summary of Contents for Invivo

Page 1: ...USER MANUAL ROKIT ...

Page 2: ... called Invivo gel for printing wide range of soft 3D cellular structures with Invivo dispensers Additionally Invivo provides uncontaminated environment by making the machine closed system with H14 grade HEPA filter for external air filtration and 254nm UV lamps for stage sterilization With android OS touchscreen users can upload download and print the 3D file with wifi network also monitor printi...

Page 3: ...mm Ø Pneumatic Dispenser 0 1 0 5mm Ø Use caution when turning on the UV lamp Do not use a work bench when a UV lamp is on It may irritate or burn skin and eyes Use a red switch on the upper right side of the machine to turn on off the UV lamp Turn off the UV lamp before opening It requires replacement every 14 months 24hours a day NOTE Keep away from flammable substances It may result in a fire Do...

Page 4: ...guage setting Identification of Serial number and IP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Dispenser Filament guide Extruder 0 2mm INVIVO PLA Pin 1 8mm Cleaning Pin Allen Wrench Bolt Thickness Gage Syringe Syringe Tip Petri Dish Dongle USB Cable Power Cable Aluminum Case 1ea 1ea 1ea 1ea 1ea 2set 3set 2set 1ea 5ea 3ea 10ea 1ea 1ea 1ea 1ea WHAT S INCLUDED 1 9 5 4 6 7 8 WHAT S IN THE BOX 10 11 12 13...

Page 5: ...ng material Click the Slicing button on the top to create the G Code file and save it 1 2 3 4 5 6 7 HOW TO USE HOW TO USE SLICER SAVE SLICER SAVE 2 2 3 1 2 1 1 2 3 1 TIP Dispenser2 Right Dispenser Dispenser1 Left Dispenser Dispenser2 Open New Creator K in your computer Click Settings Printer Bio on the top of the menu Open up a 3D modeling file such as stl obj 3ds and amf using File Open Decide th...

Page 6: ...A bed installation Click New Creator K APP Printer View on the screen To install a bed such as a petri dish adjust the bed mount position using arrow buttons like seen on the screen 1 2 HOW TO USE ...

Page 7: ...minimize layer of air inside of the syringe After choosing a proper size of a needle tip for the target resolution adjust the height of the dispenser mount to the position of the piston accordingly Move to the New Creator K APP Filament DISPENSER 1 RIGHT on the menu Click 0 1MM 1MM or 10MM on the Distance to move dispenser mounter Adjust the height of the mounter to the piston using UNLOAD or LOAD...

Page 8: ...ust the distance from a nozzle and a bed After clicking the SET HOME POSITION choose the distance to move among 0 1MM 1MM and 10MM After selecting the moving distance you want click up and down arrows to adjust the distance between an output bed and a nozzle up to the properties such as viscosities of materials The thickness gauge provided will be helpful for this Click the FINISH button to finish...

Page 9: ...er the extruder nozzle on the SET POSITION menu as much as the height of dispenser Additionally adjust the distance of a bed and a nozzle and then turn the upper screw to change the height of the extruder 1 2 3 HOW TO USE NOTE For dual leveling click the SET POSITION button and then adjust height of the extruder manually to the position of the dispenser nozzle accordingly ...

Page 10: ...elect the file to print out 1 2 3 HOW TO USE HOW TO USE Using a USB cable to print out on a computer Open the New Creator K app and click CONNECT Insert DEBUG NETWORK IP address 192 168 7 2 and click the Connect button on the right When the computer and INVIVO are connected click the Print after uploading a G code file 1 2 3 CONNECT USB ...

Page 11: ... and confirm IP address on the WiFi network Open the New Creator K app and then click CONNECT Type the NETWORK IP address 192 168 0 XXX and click the Connect button on the right When the computer and INVIVO are connected click the Print after uploading a G code file 1 2 3 4 5 HOW TO USE ...

Page 12: ...e Take out the inserted tube pressing the black one touch fitting on the top of the nozzle Remove remains of the material in the nozzle with a sterilized pin 1 2 3 4 5 HOW TO USE HOW TO USE Detaching and Keeping the bio dispenser after use Choose New Creator K APP Filament DISPENSER 1 RIGHT on the screen Click the UNLOAD button Loosen up screws holding a bio dispenser and detach the bio dispenser ...

Page 13: ...Warmer Put spare bio dispensers in the warmer as seen on the screen Enter the New Creator K APP Printer View Press TEMPERATURE to heat up the bio ink Preheat spare dispensers to use 1 2 3 4 HOW TO USE Temperature ...

Page 14: ...th process above the internal elements may be overloaded which may cause malfunction Replacement term of INVIVO COOLANT is 1 year TIP The maximum pressure is 9bar 900kpa When you have ooze while your printing Hold VACCUM which is on the Air Dispenser Controller HOW TO USE How to use Air Dispenser Premium Before using the Air Dispenser press SETTING OPTION and press ON on the Dispenser Type Bio INV...

Page 15: ... power on of Compressor Set preferred pressure by controlling the pressure gauge of Compressor 1 2 3 HOW TO USE TIP Loading of the Air Compressor starts at below 9 8bar and stops when it reaches to 11 3bar Factory setting of compressor is 9 5bar which can be controlled by pressure regulating valve Power Switch Drain Timer Hour Meter Pressure Regulating Valve Regulator Gauge Tank Gauge ...

Page 16: ...ROKIT Inc 82 02 867 0182 info rokit co kr www rokit co kr www facebook com rokitworld TEL E Mail WEB SNS USER MANUAL ROKIT ...

Reviews: