Setting the Engineering Units
To set the Engineering Units:
From the
Standby
display, press
SetUp (F4)
to go to the
Mate Configuration
display:
Press
Set Mate (F3)
to go to the
Mate Settings
display:
Press
Set Units (F1)
to go to the
Set Metal Loss Units
display:
Select and press
Mils (F1)
for mils (0.001”) and mils/year
or
press
mm (F2)
for millimeters
and mm/year
or
um (F3)
for micrometers and um/year.
After the selection is made and correctly displayed on the display, press
Exit
to set the
units and return to the
Mate Settings
display. Press
Exit
again to return to the
Mate
Configuration
display. Press
Exit
again to return to the
Standby
display.