©
ROHR
8
©
ROHR
English
DFX-15 / DFX-40 / DFX-80 / DFX-150
Mode
Change current between 2A/8A/15A by pressing this button. Settings can be changed during charging.
Battery Type
Change battery type between STD/AGM/CAL by pressing this button. Settings can be changed during
charging.
Amp
Show current on the LCD display by pressing this button.
Volt
Show voltage on the LCD display by pressing this button.
Recon
Repair sulphated batteries by pressing Recon button. If batteries can’t be repaired, the ‘battery / voltage
warning’ symbol will be displayed. Other buttons will be invalid under Recon mode. Exit Recon mode by
pressing Recon button again.
Charging status
This column will show charging status. It will be moving during charging and stop moving after battery is
full.
Connection indication
Shows various connection status’s / issues:
•
No Connection
•
Loose Connection
•
Reverse Polarity
Battery / voltage warning
• Bad battery - the battery is in bad condition and may need to be replaced.
•
High voltage -
you may have choosen the wrong voltage, for example, charging a 12V battery with
6V mode or a 24V battery with 12V mode.
Battery / voltage warning
Displayed when there is a high temperature. Stop operation.
Note.
This charger has memory function. It will return to last mode you chose next time the charger is
connected. The default setting is 2A current, STD battery type.