FEDL22594-06
ML22594-XXX
38/73
4. FAD command
command
0
0
0
0
1
1
0
0
1st byte
0
0
0 0
FAD3
FAD2
FAD1
FAD0
2nd byte
The FAD command is used to set the fade-in time for the speaker amplifier.
The fade-in time cna be adjusted through 16 levels, as shown in the table below. The initial value after reset is
298
µ
s. When the PUP command is input, the value set by the FAD command is initialized (298
µ
s).
FAD3–0
Fade-in time (
µ
s)
F
442
E
422
D
401
C
381
B
360
A
340
9
319
8
298 (initial value)
7
278
6
257
5
237
4
216
3
195
2
175
1
154
0
134