INSTALLATION INSTRUCTIONS

MAINTENANCE AND CARE INSTRUCTIONS CONTINUED 

Flushing the Instant Hot Water Tank 

It is recommended that the user flushes through the system completely by drawing off 
the instant hot water and allowing to reheat and repeating the process for a further 2 or 3 
times to ensure the system is fully operational. 

Water Draw Back and Contamination in the Tank 

During the filling of any vessel the user must ensure at all times that the spout outlet is 
not submerged in the water during the dispensing of the instant hot water and especially 
when the instant hot water handle is released.

 

 

Maintenance & Power Saving 

If the electronic instant hot water appliance is not being used for long periods of time ie: 
over 2 days, to save power we recommend you switch off using the  “ON/OFF” switch.  

Seasonal Shutdown 

The hot water system (tank and Dispenser) must not be exposed to freezing tempera-
tures. If there is a possibility of this the system must be drained of water. Shut-off the 
mains supply and unplug the unit from the electricity mains and allow the tank to cool for 
at least 1 hour. Disconnect the inlet supply to the tank and remove the silicone hose out-
let pipe, lift the unit to the sink, turn upside down and drain all the water from the tank. 
When re-installing follow the original installation instructions. 
 

The electronic instant hot water appliance like any water heater has a limited operational 
life span and will eventually fail. In order to ensure maximum protection and to avoid possi-
ble damage to any property or personal injury the electronic instant hot water appliance 
should be inspected regularly for any water leakage or damage.  

Regularly check for any signs of water leakage, if there is any water leakage then replace any 
loose or split silicon tubes or flexi tails which can cause water leakage and damage. 

To provide additional water security to avoid property damage the electronic instant hot 
water appliance can be placed in a drain pan and connected to a suitable drain outlet to 
avoid any water damage. The drain pan should be installed using the manufacturers installa-
tion instructions.  

NOTICE  

houseofrohl.com

Consult your local House of Rohl showroom for additional information and specifications. For complete warranty details and a list of showrooms, go to houseofrohl.com

Summary of Contents for Perrin & Rowe GEORGIAN ERA U.KIT1307

Page 1: ...ridge PERRIN ROWE GEORGIAN ERA C SPOUT HOT WATER FAUCET TANK AND FILTER KIT U KIT1307 Ø1 1 4 HOLE 6 1 2 5 1 2 1 3 4 MAX Ø1 7 8 10 3 3 4 2 3 8 12 1 2 9 8 TO HOT TANK INLET FROM FAUCET Ø2 PLEASE ALLOW 12 1 2 MINIMUM TO ALLOW FOR FILTER REPLACEMENT 11 3 4 7 1 2 Ø1 3 4 5 year Limited Warranty on Faucet 3 year Limited Warranty on Tank No Warranty Polished Chrome Polished Nickel Satin Nickel English Bro...

Page 2: ...S TO MINIMISE RISK AND POTENTIAL INJURY TWO ACTION OPERATION SPRING BACK VALVE AND DELAYED DELIVERY BUT SHOULD BE OPERATED OR SUPERVISED BY A RESPONSIBLE ADULT PLEASE READ AND FULLY UNDERSTAND THE HEATER TANK INSTRUCTIONS BEFORE USE Registration Please visit www rohlhome com filtration registration aspx complete the registration card postage paid or phone 1 800 777 9762 to register your product O1...

Page 3: ...ser Feed the flexible connections through the ø1 1 4 work surface hole ensuring the base seal is in place between tap and mounting surface Ensure the base ring and tap are orientated correctly Hot water lever should rotate to point forwards The spout fixing screw should be at the back Secure by using the clamping plate and nuts box spanner is provided Attach the flow regulator 9 16 to the Cold inl...

Page 4: ...1106 and heater tank U 1998 See separate filter guide and heater tank installation for further installation instructions Mount the filter housing in an accessible location using either screws in the bracket or the adhesive pad ensuring the mounting area is clean by using the wipe provided Once the mains connections are made fit the G3 8 braided hose to the filter as shown Connect the silicone tube...

Page 5: ...age the plated finish and void your warranty BEFORE USE Carefully check the installation for leaks If further building work is to be carried out in the vicinity cover the mixer tap to avoid damaging the finish Please ensure that the installation complies with the local plumbing codes NOTE Diagram shows set up with u 1998 he tank and u 1106 filte ROHL WARRANTY POLICY All products supplied by ROHL c...

Page 6: ...Please read these instructions fully before commencing the installation and operation of the Electronic Instant Hot Water Appliance houseofrohl com Consult your local House of Rohl showroom for additional information and specifications For complete warranty details and a list of showrooms go to houseofrohl com ...

Page 7: ...uld only be installed by a competent person if you feel for any reason unsure about the installation please contact a qualified plumber or electrician to install the appliance Make sure all electrical wiring and connections conform to local standards Make sure all water connections conform to local standards Make sure all electrical wiring and water connections conform to local codes Standard 120v...

Page 8: ...Shock Using an ungrounded connection or improper connection of the power sup ply to the product can result in a serious injury or death from electrical shock Electric Shock Do not remove the earthing terminal Do not reconstruct the plug Do not disassemble main box and any part for the power Important The instructions are only intended as a guide if there is any doubt then please contact a certifie...

Page 9: ...ure the front of the unit is visible and the front temperature dial can be easily reached Do not attempt to open modify or service this electronic instant hot water appliance Re pairs should be carried out by Authorised Service personnel Opening the unit will void the guarantee The required water supply pressure is a minimum of 22psi to maximum of 72psi Turn off all controls before unplugging Do n...

Page 10: ...wise the pipes and the Dispenser and tank will be frozen and there will be serious safety trouble possible bodily injury acci dents and damaged caused and the guarantee will be void It s forbidden to wash the electronic instant hot water appliance with water directly The installation environment should be ventilated with protection from the direct sun shine When installing the electronic instant h...

Page 11: ...nic instant hot water appliance is not under pressure consequently there is a slight delay in water flow after the hot water springback Dispenser handle has been turned on This is normal and indicates that the electronic instant hot water appliance is function ing properly It is recommended that you have access to a separate power circuit serving only your elec tronic instant hot water appliance S...

Page 12: ... socket it must be tested for water tightness and no leaks Open all water valves to allow water to flow to the instant hot water Dispenser Turn the spring back instant hot water handle and hold to fill the electronic instant hot water appliance this will take about 90 seconds When the electronic instant hot water appliance is full water will flow from the instant hot water Dispenser spout Initiall...

Page 13: ...gs 208 F max 206 F 203 F 194 F 185 F 176 F 167 F To turn on the electronic instant hot water appliance touch the button and hold for 3 seconds until the display lights up Touch the button and press each time so that the temperature settings will change from 167 F to 176 F to 194 F to 185 F to 194 F to 203 F to 206 F to 208 F continue to press till the required temperature is seen To confirm the te...

Page 14: ...low the tank to cool for at least 1 hour Disconnect the inlet supply to the tank and remove the silicone hose out let pipe lift the unit to the sink turn upside down and drain all the water from the tank When re installing follow the original installation instructions The electronic instant hot water appliance like any water heater has a limited operational life span and will eventually fail In or...

Page 15: ...the circuit breaker and fuse are working correctly Turn on the power and touch the on off button and then set the required temperature and confirm the heat up Water is too hot Water temperature setting on display panel is set to high Re set the temperature to the required temperature and con firm the heating up Water is dripping from the instant hot water Dispenser spout The expansion chamber isn ...

Page 16: ...olume of water has been drawn off there may a slightly longer delay in the wa ter appearing from the instant hot water Dispenser spout Check length of silicon pipe No Water Flowing Water Valves have been turned off Inlet Pipes have been twisted or blocked Turn on all the water valves Ensure the pipes are not twisted or kinked to restrict flow Remove and clean the aerator IF YOU ARE IN ANY DOUBT TH...

Page 17: ...lhome com Guarantee Void Unless The Water Filter Is Replaced Every 6 Months Issue PRV114112017 Rohl Perrin Rowe are Registered trade marks houseofrohl com Consult your local House of Rohl showroom for additional information and specifications For complete warranty details and a list of showrooms go to houseofrohl com ...

Page 18: ...ady to use it is vitally important that you follow the process below to ensure that all air is bled from the system P Pl la ac ce e a a j ju ug g u un nd de er r t th he e s sp po ou ut t a as s w wa at te er r w wi il ll l s sp pl lu ut tt te er r f fr ro om m t th he e s sp po ou ut t u un nt ti il l a al ll l o of f t th he e a ai ir r i is s e ex xp pe el ll le ed d Operate the instant hot tap...

Page 19: ... th ho or ro ou ug gh hl ly y c ch he ec ck k t th he e u un ni it t f fo or r a an ny y w wa at te er r l le ea ak ks s b be ef fo or re e y yo ou u c co on nt ti in nu ue e 2 G3 8 BRAIDED HOSE FROM TAP PUSH FIT BRAIDED HOSE TO HEATER TANK DIRECTION OF FLOW Fixing Mounting Bracket Attaching Hoses FILTER SUMP 9 16 DOMESTIC HOT IN 9 16 COLD IN 3 System Layout DIRECTION OF FLOW G3 8 BRAIDED HOSE FRO...