Command Reference
R&S
®
ZNB/ZNBT
816
User Manual 1173.9163.02 ─ 38
<Cmp>
Must be omitted or set to 1.
Parameters:
<CircuitModel>
SHLC
Currently only the "Shunt L, Shunt C" lumped element model is
supported
<Conductance>
Range:
-10 MS to 10 MS.
Increment: 1 μS (1E-6 F)
*RST:
0 S
Default unit: S(iemens)
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:DIFFerential:EMBedding<LogPt>:
PARameters:L<Cmp>
<CircuitModel>[, <Inductance>]
Specifies the inductance value L in the "Shunt L, Shunt C" lumped element model for
differential match embedding.
In the query form, the <Inductance> parameter must be omitted.
Suffix:
<Ch>
.
Channel number
<LogPt>
Logical port number (balanced port)
<Cmp>
Must be omitted or set to 1
Parameters:
<CircuitModel>
SHLC
Currently only the "Shunt L, Shunt C" lumped element model is
supported
<Inductance>
Range:
-1 H to 1 H
Increment: 1 pH (1E-12 H)
*RST:
1 nH (1E-9 H)
Default unit: H
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:DIFFerential:EMBedding<LogPt>:
PARameters:R<Cmp>
<CircuitModel>[, <Resistance>]
Specifies the resistance value R in the "Shunt L, Shunt C" lumped element model for
differential match embedding.
In the query form, the <Resistance> parameter must be omitted.
Suffix:
<Ch>
.
Channel number
<LogPt>
Logical port number (balanced port)
<Cmp>
Must be omitted or set to 1.
SCPI Command Reference