GUI Reference
R&S
®
ZNB/ZNBT
354
User Manual 1173.9163.02 ─ 38
●
The measurement parameters are channel specific. However only one configura-
tion can be can be measured at a time.
●
Voltage and current measurements on the RFFE and GPIO pins are only possible
with
Var. 03
of the extension board R&S
ZN-B15/Z15.
Output Voltage
Defines the output voltages for the voltage/current measurements on the RFFE pins.
Note:
The Data and Clock pins always use the same output voltages; their values can-
not be set independently.
settings will not be activated until
is
pressed.
Remote command:
CONTrol<Ch>:RFFE<Bus>:TEST:DATA
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk
CONTrol<Ch>:RFFE<Bus>:TEST:VIO
Range / Shunt
Defines the current range for the voltage and current measurement on the respective
RFFE pin. The analyzer firmware automatically selects a suitable shunt resistance.
and "Range" / "Shunt" settings will not be activated until
is
pressed.
Remote command:
Set
Use the "Set" button to apply all RFFE/GPIO configuration changes and to activate the
configured voltage and
settings on the RFFE/GPIO pins.
Remote command:
Channel Config Softtool