Remote control commands
R&S
®
SMM100A
957
User Manual 1179.1341.02 ─ 05
Parameters:
<Logarithmic>
float
The unit is mandatory.
Range:
0.01 to 100
Increment: 1E-3
*RST:
1
Default unit: PCT
Example:
See
Example "Setup an RF frequency or power sweep"
Manual operation:
See
"Step Linear/Step Logarithmic"
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear]
<Linear>
Sets the step width for linear sweeps.
See
Chapter 7.10.2.1, "Correlating parameters in sweep mode"
Omit the optional keywords so that the command is SCPI-compliant.
Parameters:
<Linear>
float
Range:
0.001 Hz to (STOP - STARt)
Increment: 0.01
Example:
See
Example "Setup an RF frequency or power sweep"
Manual operation:
See
"Step Linear/Step Logarithmic"
[:SOURce<hw>]:COMBined:FREQuency:STARt
<CombFreqStart>
Sets the start frequency of the combined RF frequency / level sweep.
See
Chapter 7.10.2.1, "Correlating parameters in sweep mode"
Parameters:
<CombFreqStart>
float
Range:
-59999E5 to 12E9
Increment: 0.01
*RST:
100E6
Example:
See
Example "Setup an RF frequency or power sweep"
[:SOURce<hw>]:COMBined:FREQuency:STOP
<CombFreqStop>
Sets the end frequency of the combined RF frequency / level sweep.
SOURce subsystem