Configuring the RF signal
R&S
®
SMM100A
397
User Manual 1179.1341.02 ─ 05
2. If you already have created a file with user correction data:
a) Select "UCOR Data > navigate to the file *.uco > Select".
b) Proceed with
3. If you need to create a file:
a) Select "UCOR Data > New".
b) Enter the filename
UCOR_Data
and confirm with "Ok".
c) Choose the file and confirm with "Select".
d) Select "Edit UCOR Data".
e) To fill the user correction data table, proceed as described in
4. Select block diagram > RF > "On".
5. Select "State > On".
The "UCOR" dialog contains all settings for creating and handling files with user-
defined level correction values.
The remote commands required to define these settings are described in
ter 13.16.5, "SOURce:CORRection subsystem"
Settings
State
Activates user correction.
The R&S
SMM100A displays the status icon "Lev Ucor" in the status bar.
User correction cannot be activated simultaneously with absolute level compensation
based on user-defined frequency response values. These functions exclude each
other; you can one only of them at a time.
See user manual R&S
SMM-K544 User-Defined Frequency Response Correction.
Improving level performance