Configuring the RF signal
R&S
®
SMM100A
347
User Manual 1179.1341.02 ─ 05
"Auto"
Generates the signal by processing the frequency/level value pairs of
the list from the beginning to the end.
The list steps are performed automatically, controlled by the dwell
time. If you switch from any mode to "Auto", signal generation always
starts at the top of the list.
"Single / Extern Single"
Generates the signal by processing the frequency/level value pairs of
the list once from the beginning to the end after a trigger event.
The list steps are performed automatically, controlled by the dwell
time. If one cycle is completed, the instrument waits for the next trig-
ger event.
"Step / Extern Step"
Generates the signal by processing the frequency/level value pairs of
the list step-by-step, manually triggered.
Remote command:
[:SOURce<hw>]:LIST:TRIGger:SOURce
Dwell Time Mode
Selects either variable dwell times or a fixed dwell time to perform signal generation in
list mode.
"Global"
Uses the same dwell time for all lists steps, set with
"From List"
Uses the dwell times from the list.
You can define the dwell time for each frequency/level value pair indi-
vidually, see
Remote command:
Global Dwell Time
Sets the dwell time for
> "Global".
Note:
In case of considerable overrun conditions, the R&S
SMM100A turns off the list
mode.
See also
Remote command:
Run Mode
Selects whether the instrument generates the signal by processing the list directly, or
by learning and replaying the data.
"Learned (Frozen RF Settings)"
Generates the signal with the previously learned and stored data from
the temporary memory.
Varying the RF signal in list or sweep mode