Configuring the internal baseband source
R&S
®
SMM100A
157
User Manual 1179.1341.02 ─ 05
4.6.3.2
Sine test signals
Access:
► Select "Baseband > ARB > General > Test Signal Form > Sine" and press "Create
Test Signal".
This dialog provides settings for configuration of a sinusoidal test signal. A sine
wave is generated on the I path, and a sine wave of the same frequency but
phase-shifted is generated on the Q path. For more information, refer to
ter 4.6.2.2, "ARB test signals"
The dialog displays the characteristic of the currently selected signal.
Settings:
Frequency
Enters the frequency of the test signal.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:FREQuency
Samples per Period
Enters the number of sample values required from the sine wave per period.
The maximum allowed value is determined by the maximum ARB clock rate (see data
sheet) and the selected frequency.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:SAMPles
Using the arbitrary waveform generator (ARB)