Configuring the internal baseband source
R&S
®
SMM100A
114
User Manual 1179.1341.02 ─ 05
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay
4.4.2.3
Clock settings
Access:
► Select "Baseband > Custom Dig Mod > Clock".
The tab provides clock source settings.
Settings:
Clock Source
Selects the clock source.
●
"Internal"
The instrument uses its internal clock reference.
See also
Remote command:
[:SOURce<hw>]:BB:DM:CLOCk:SOURce
[:SOURce<hw>]:BB:ARBitrary:CLOCk:SOURce
[:SOURce<hw>]:BB:MCCW:CLOCk:SOURce
4.4.2.4
Local and global connectors settings
Each of the "Trigger In", "Marker" and "Clock" dialogs and the "Trigger Marker Clock"
dialog provides a quick access to the related connector settings.
See also
Chapter 11.2, "Configuring local and global connectors"
Common functions and settings in the baseband domain