[:SOURce<hw>]:FREQuency:STEP:MODE
<Mode>
Activates (
USER
) or deactivates (
DECimal
) the user-defined step width used when
varying the frequency value with the frequency values
UP/DOWN
. The command is
linked to the command "Variation Active" for manual control, i.e. the command also
activates/deactivates the user-defined step width used when varying the frequency
value with the rotary knob.
Parameters:
<Mode>
DECimal | USER
*RST:
DECimal
Example:
FREQ:STEP 50 kHz
sets the step width for the frequency setting to 50 kHz.
FREQ:STEP:MODE USER
actives this step width for frequency variation with the rotary
knob (manual control) and with frequency values
UP/DOWN
(remote control).
Manual operation:
See
7.16.8 SOURce:INPut Subsystem
The
SOURce:INPut
subsystem contains the commands for configuring the inputs for
trigger, data and control signals. A common trigger threshold and input impedance is
effective for all trigger and control signal inputs.
The settings influence the digital modulations, the generation of waveforms or multicar-
rier signals, and all digital standards. Irrespective of this, a common threshold and
input impedance is effective for the serial and parallel data input (Path A only). These
data sources are available for digital modulation ("Custom Digital Modulation").
[:SOURce]:INPut:CLOCk:IMPedance
............................................................................... 742
[:SOURce<hw>]:INPut:MODext:IMPedance
......................................................................743
[:SOURce]:INPut:TRIGger:BBANd:SLOPe
........................................................................743
[:SOURce]:INPut:TRIGger:IMPedance
............................................................................. 743
.....................................................................................744
................................................................................... 744
[:SOURce]:INPut:DELay:ADCState
..................................................................................745
[:SOURce]:INPut:DELay:SPOSition
................................................................................. 745
[:SOURce]:INPut:DELay:CLENgth<ch>
............................................................................745
[:SOURce]:INPut:CLOCk:IMPedance
<Impedance>
Selects the input impedance for the clock inputs. 1kOhm/GND should be selected for
high clock rates.
The setting affects the CLOCK IN BNC connector at the rear of the instrument.
SOURce Subsystem