![Rohde & Schwarz SMBV100A Operating Manual Download Page 760](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735760.webp)
Remote Control Commands
R&S
®
SMBV100A
745
Operating Manual 1176.8016.02 ─ 17
Manual operation:
See
[:SOURce]:INPut:DELay:ADCState
<State>
Enables/disables the automatic delay compensation.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
see example for
[:SOURce]:INPut:DELay:CLENgth<ch>
Manual operation:
See
"Automatic Delay Compensation"
[:SOURce]:INPut:DELay:SPOSition
<Position>
Defines the position of the slave instrument in the daisy chain. The slave directly con-
nected to the master instrument is the one with number 1.
Parameters:
<Position>
integer
Range:
1 to 10
*RST:
1
Example:
see example for
[:SOURce]:INPut:DELay:CLENgth<ch>
Manual operation:
See
"Automatic Delay Compensation"
[:SOURce]:INPut:DELay:CLENgth<ch>
<CableLength>
Sets the total length of the cable used to connect the CLK OUT and CLK IN connec-
tors. For the first slave in the chain, the value represents the cable length between the
master and the first slave; for the second slave, the cable length to the first
and
to the
second has to be defined, etc.
Parameters:
<CableLength>
float
Range:
0 to 10
Increment: 0.01
*RST:
0.5
Example:
Setting in the first slave instrument Slave#1:
:SOURce:INPut:DELay:SPOSition 1
:SOURce:INPut:DELay:CLENgth1 1
:SOURce:INPut:DELay:ADCState ON
SOURce Subsystem