Remote-control commands
R&S
®
SMW-K52/-K116
70
User Manual 1175.6778.02 ─ 19
RATio
A regular marker signal that is defined by an on/off ratio
*RST:
RESTart
Example:
See
Example "Configuring marker settings"
Manual operation:
See
[:SOURce<hw>]:BB:DVB:TRIGger:OUTPut<ch>:ONTime
<Ontime>
[:SOURce<hw>]:BB:DVB:TRIGger:OUTPut<ch>:OFFTime
<OffTime>
Sets the number of samples during which the marker output is on or off.
*)
If R&S
SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See chapter "Basics on ..." in the R&S
SMW user manual.
Parameters:
<OffTime>
integer
Range:
1 (R&S
SMW-B10) / 1* (R&S
SMW-B9) to
16777215
*RST:
1
Example:
See
Example "Configuring marker settings"
Manual operation:
See
[:SOURce<hw>]:BB:DVB:TRIGger:OUTPut<ch>:PATTern
<Pattern>, <BitCount>
Defines the bit pattern used to generate the marker signal.
Parameters:
<Pattern>
numeric
0 = marker off, 1 = marker on
*RST:
#H2
<BitCount>
integer
Range:
1 to 64
*RST:
2
Example:
See
Example "Configuring marker settings"
Manual operation:
See
[:SOURce<hw>]:BB:DVB:TRIGger:OUTPut<ch>:PULSe:DIVider
<Divider>
Sets the divider for pulse marker mode (
PULSe
).
*)
If R&S
SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See chapter "Basics on ..." in the R&S
SMW user manual.
Marker commands