Page 1: ...R S NRP Series Power Sensors Getting Started Getting Started Version 10 1419017002 C1 2...

Page 2: ...tion CD ROM included in delivery Rohde Schwarz would like to thank the open source community for their valuable contribution to embedded computing 2018 Rohde Schwarz GmbH Co KG M hldorfstr 15 81671 M...

Page 3: ...ic Safety Instructions and the product documentation in a safe place and pass them on to the subsequent users Riesgo de lesiones y da os en el instrumento El instrumento se debe usar de manera adecuad...

Page 4: ...die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter Risque de blessures et d endommagement de l appareil L appareil doit tre utilis conform ment aux prescript...

Page 5: ...Safety 8 3 Key Features 9 4 Preparing for Use 10 4 1 Unpacking and Checking the Power Sensor 10 4 2 Operating Conditions 10 4 3 Important Aspects for Test Setup 11 4 4 Connecting to a DUT 11 4 5 Conn...

Page 6: ...3 Remote Control 32 6 4 R S NRPV 32 6 5 R S Power Viewer 34 6 6 R S Power Viewer Mobile 37 6 7 R S NRX 37 6 8 R S NRP2 38 7 Remote Control Interfaces and Protocols 41 7 1 USB Interface 41 7 2 Ethernet...

Page 7: ...t Includes basic operations and general information e g safety instructions etc A printed version is delivered with the power sensor 1 2 User Manuals Contains the description of all instrument modes a...

Page 8: ...www rohde schwarz com brochure datasheet nrp18s www rohde schwarz com brochure datasheet nrp t tn www rohde schwarz com brochure datasheet nrp twg 1 7 Release Notes and Open Source Acknowledgment OSA...

Page 9: ...mentation Overview R S NRP Series 7 Getting Started 1419 0170 02 10 www rohde schwarz com application nrp_s_sn www rohde schwarz com application nrp18s Application Notes Application Cards White Papers...

Page 10: ...nt users Safety information is part of the product documentation It warns you about the poten tial dangers and gives instructions how to prevent personal injury or damage caused by dangerous situation...

Page 11: ...are available with an additional Gigabit Ethernet interface with Power over Ethernet PoE power supply The power sensors with networking capabili ties the R S NRP LAN power sensors are marked with a tr...

Page 12: ...gh hot surfaces Applies only to the R S NRP18S xx power sensors Under certain conditions the maximum surface temperatures of the power sensor can exceed the limits defined in EN 61010 1 Provide protec...

Page 13: ...charge ESD Electrostatic discharge ESD can damage the electronic components of the power sensor and the device under test DUT Ground yourself to avoid electrostatic discharge ESD damage Use a wrist st...

Page 14: ...sk of damaging the center pin of the RF connector Always rotate only the hex nut of the RF connector Never rotate the power sensor itself Tighten the RF connector manually 4 To ensure maximum measurem...

Page 15: ...able Setup NRP 3 Path Diode Power Sensor MHz to GHz 100 pW to 200 mW 70 dBm to 23 dBm SMART SENSOR TECHNOLOGY Figure 4 1 Setup with an R S NRP ZKU cable 1 Signal source 2 R S NRP power sensor 3 Host i...

Page 16: ...ment 1 to 4 R S NRP power sensors 1 R S NRP ZK6 cable per sensor R S NRP Z5 sensor hub with external power supply unit and USB cable BNC cables to connect the trigger input and trigger output signals...

Page 17: ...vered external power supply unit to the R S NRP Z5 and to an AC supply connector f Connect the trigger input of the R S NRP Z5 with a BNC cable to the trigger source optional g Connect the trigger out...

Page 18: ...upporting PoE power delivery e g R S NRP ZAP1 7 Computer 1 Connect the RF connector of the sensor to the DUT 2 NOTICE Risk of sensor damage Use only PoE power sourcing equipment PSE according to IEEE...

Page 19: ...on PoE Ethernet switch 10 Computer 1 Connect the RF connector of the sensor to the DUT 2 NOTICE Risk of sensor damage Use only PoE power sourcing equipment PSE according to IEEE standards 802 3af or I...

Page 20: ...2 3at Otherwise your power sensor can get damaged Connect the RJ 45 Ethernet connector of the sensor to the output of the PoE injec tor 3 Connect the PoE injector to a power supply 4 Connect the compu...

Page 21: ...wer sensor 3 Check that the remaining main network adapter has been assigned an IP address starting with 169 254 The IANA Internet assigned numbers authority has reserved the range 169 254 0 0 to 169...

Page 22: ...power sensor try the default hostname as well as the hostname extended with local as shown in the example below All communica tion for resolving names in the top level domain TLD local are defined to...

Page 23: ...respectively if a network or a point to point connection is used 4 6 Connecting to a USB Host For connecting the power sensor to a USB host use the host interface of the power sensor For details see C...

Page 24: ...1 RF connector see Chapter 5 1 RF Connector on page 22 2 Trigger I O connector see Chapter 5 2 Trigger I O Connector on page 24 3 Host interface connector see Chapter 5 3 Host Interface on page 24 4 S...

Page 25: ...RP18SN R S NRP33S 3 50 mm 3 50 mm 2 92 mm SMA 0 90 Nm 8 lbs R S NRP33SN R S NRP33SN V R S NRP40S 2 92 mm 3 50 mm 2 92 mm SMA R S NRP40SN R S NRP50S 2 4 mm 2 4 mm 1 85 mm R S NRP50SN Table 5 3 R S NRP1...

Page 26: ...an input for signals if the trigger source parameter is set to EXTernal2 It is used as an output for trigger signals if the sensor is operated in the trigger master mode Further information For detail...

Page 27: ...rror You can query the error type with SYSTem SERRor Note If this state occurs after a firmware update the update was not successful Perform the firmware update again 5 5 LAN PoE Interface Available o...

Page 28: ...he sensor is powered over PoE You can operate it using the Ethernet interface No light No PoE power is present Network status LED Available only for LAN power sensor The network status LED shows wheth...

Page 29: ...ll power sensors The components of the R S NRP Toolkit depend on the operating system 6 1 1 Versions and Downloads The R S NRP Toolkit is available for the Microsoft Windows operating systems listed u...

Page 30: ...tems contains the components described in the release notes available at www rohde schwarz com software nrp tool kit Installing on a computer 1 Start the R S NRP Toolkit installer on the Windows based...

Page 31: ...tablishing a LAN connection with an R S NRP LAN power sensor The tool provides the following functions Configuring the network settings by temporary connecting the selected sensor to the computer usin...

Page 32: ...nterface Requires a power sensor with networking capabilities a R S NRP LAN power sensor With the integrated browser based graphical user interface of the LAN power sensor you can easily configure the...

Page 33: ...he R S NRP power sensors can damage the power sensors or lead to erroneous results Ensure that you connect disconnect your power sensor as described in Chapter 4 Preparing for Use on page 10 Starting...

Page 34: ...power sensor easily The change to remote control occurs on the fly and has no influence on the manual operation Further information See the user manual for details Chapter 7 Remote Control Interfaces...

Page 35: ...4 R S NRP ZKU cable 5 USB connector 6 Computer with installed R S NRPV Incorrectly connecting disconnecting the R S NRP power sensors can damage the power sensors or lead to erroneous results Ensure...

Page 36: ...t Measure Continuous The Continuous measurement window appears It shows the measurement results numerically and the control panel for accessing further dialogs with param eters for measurement evaluat...

Page 37: ...obile For details see Chapter 6 6 R S Power Viewer Mobile on page 37 Setup Figure 6 3 Setup with the R S Power Viewer 1 Signal source 2 R S NRP power sensor 3 Host interface connector 4 R S NRP ZKU ca...

Page 38: ...us average measurement select Measurement Continuous The Continuous measurement window appears It shows the measurement results numerically and some parameters that can be configured 6 To start the me...

Page 39: ...S NRX you can measure power with up to four power sensors simultane ously You can use all sensor dependent measurement functions and display the results in parallel Required equipment R S NRP power s...

Page 40: ...ettings dialog select the Measurement Type for example Continuous Average b Tap Quick Setup Auto Set 4 Switch on the signal source The measurement starts and the result is displayed in dBm 5 If necess...

Page 41: ...as described in Chapter 4 Preparing for Use on page 10 Starting a measurement 1 Connect the cables as shown in Figure 6 5 a Connect the R S NRP ZK6 cable to the host interface connector of the sensor...

Page 42: ...ppropriate softkey to select a specific sen sor for zeroing 4 Press the FREQ hardkey and enter the carrier frequency of the applied signal if the specified measurement accuracy is to be reached 5 Swit...

Page 43: ...tandardized software interface library providing input and output functions to communicate with instruments A VISA installation on the controller is a prerequisite for remote control over USBTMC and L...

Page 44: ...uct ID for the Rohde Schwarz sensor serial number is the individual serial number on the rear of the sensor Table 7 2 R S NRPxxA N USB product IDs R S NRP power sensor USB product ID R S NRP6A 0x0178...

Page 45: ...3 Example USB 0x0AAD 0x00E2 100001 0x0AAD is the vendor ID for Rohde Schwarz 0x00E2 is the product ID for the R S NRP8S power sensor 100001 is the serial number of the particular power sensor 7 2 Ethe...

Page 46: ...Alternatively the IP address is deter mined with a procedure called Zeroconf You can also assign a LAN device name which defines the protocol characteristics of the connection See the description of t...

Page 47: ...ocol which in turn relies on TCP IP as the network transport layer The TCP IP network protocol and the associated network services are preconfigured TCP IP ensures connection oriented communication wh...

Page 48: ...e application note at http www rohde schwarz com appnote 1MA208 7 2 4 Socket Communication An alternative way for remote control of the software is to establish a simple TCP IP connection to the devic...

Page 49: ...ctrostatic discharge ESD 11 Ethernet interface Remote control 43 F Firmware update 29 G Getting started 5 H HiSLIP Protocol 45 Resource string 44 Hostname 19 I Instrument security procedures 5 Interfa...

Page 50: ...interface 41 VISA resource strings 44 VXI 11 protocol 45 Resource string HiSLIP 44 Socket 44 VISA 44 VXI 11 44 RF connector 11 22 S S parameter update 30 Safety information 8 10 Safety instructions 6...