NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
46
User Manual 1178.5689.02 ─ 06
Depending on your hardware configuration, there are dependencies between some
parameters. Configure the settings in the following order to access all possible values:
1. Select the signaling unit. See
In a multi-CMW setup, this action selects also the instrument.
2. Select the RF connector.
3. Select the RF converter.
Figure 2-22: RF path settings
......................................................................................46
........................................................................................46
........................................................................ 47
......................................................................................47
........................................................................................47
........................................................................ 47
RF Output (TX)
The following parameters configure the RF output path of the R&S
CMW.
Connector, Converter ← RF Output (TX)
Selects the output path for the generated RF signals, that means the output connector
and the TX module.
Remote command:
ROUTe:NIOT:SIGN<i>:SCENario[:FLEXible]:SCELl
External Attenuation ← RF Output (TX)
Defines the value of an external attenuation (or gain, if the value is negative) in the out-
put path. With an external attenuation of x dB, the power of the generated signal is
increased by x dB. The actual generated levels are equal to the displayed values plus
the external attenuation.
If a correction table for frequency-dependent attenuation is active for the chosen con-
nector, the table name and a button are displayed. Press the button to display the table
entries.
GUI Reference