Functions
R&S
®
OSP
193
User Manual 1178.7100.02 ─ 05
Show As List ← Path Selection
Access: "Path Switching" > "Context Menu" > "Path Selection" > "Show As List"
Only available, if at least one relay or channel is selected, as in
ple.
Displays a comma-separated list of all selected relays or channels and their switching
states, together with the number of the module and frame that these relays or channels
are in.
For example, if your selection includes relay number
6 in module M03 in frame F01,
and the relay is in state "00", the entry in the list is "F01M03(0006)". This entry is
embedded in a list of all selected relays and channels. The syntax of this list string is
compatible with the
for the R&S
OSP.
Figure 5-37: Example of a list that represents the selection of 30 relays and channels
To complete the syntax required for RC commands, the list string starts with the char-
acters "
(@
" and ends with an additional "
)
".
To copy the list for using it as a "channel list string" in the definition of RC commands,
proceed as follows, using a mouse and keyboard:
, use the left mouse button to select and
highlight the string. You can also triple-click the string or use the key combination [Ctrl]
+[A] to select the whole string. Then press [Ctrl]+[C] to copy the string.
The copied string is now in the clipboard memory of your control device. This clipboard
content is especially useful, if your control device is the same computer that you use
for defining remote control commands.
Remote command:
Load from Existing Path ← Path Selection
Access: "Path Switching" > "Context Menu" > "Path Selection" > "Load from Existing
Path"
Only available, if at least one path is saved in the device.
Loads one of the existing (previously defined) paths and performs two tasks:
●
Path Switching